Test Data
Commission Regulation (EC) No 1275/2008 Requirements
Mode
Ecodesign requirements (since January 7, 2013)
Off mode
Power consumption in off mode:
The power consumption of the product in any form
of off-mode condition must not exceed 0.50 W.
Standby
Power consumption in standby mode(s):
mode
Power consumption of the product in any
condition providing only a reactivation function, or
providing only a reactivation function and a mere
indication of enabled reactivation function must not
exceed 0.50 W.
Power consumption of the product in any condi-
tion providing only information or status display,
or providing only a combination of a reactivation
function and information or status display, must not
exceed 1.00 W.
Seasonal space heating energy efficiency
Description
Seasonal space heating energy efficiency in active mode-η
For electric local space heaters-η
The electric to primary energy
F(1) is a correction factor accounting for a positive contribution to the seasonal space
heating energy efficiency of electric storage local space heaters due to adjusted
contributions for options for heat storage and output; and a negative contribution
to seasonal space heating efficiency for commercial local space heaters due to
adjusted contributions for options for the heat output, expressed in %;
F(2) is a correction factor accounting for a positive contribution to the seasonal
space heating energy efficiency due to adjusted contributions of controls of indoor
heating comfort, the values of which are mutually exclusive, cannot be added to
each other, expressed in %;
F(3) is a correction factor accounting for a positive contribution to the seasonal
space heating energy efficiency due to adjusted contributions of controls for indoor
heating comfort the values of which can be added to each other, expressed in %;
F(4) is a correction factor accounting for a negative contribution to the seasonal
space heating energy efficiency by auxiliary electricity consumption, expressed in %;
F(5) is a correction factor accounting for a negative contribution to the seasonal
space heating energy efficiency by energy consumption of a permanent pilot flame,
expressed in %.
Seasonal space heating energy efficiency-η
Verdict
th
"
conversion coefficient"-CC
S
7
Result/remark
0.00 W
S,on
Verdict
P
N/A
N/A
Value
40 %
-
-
0.00 %
6.00 %
0.00 %
0.00 %
0.00 %
36.00 %
P

Werbung