Herunterladen Inhalt Inhalt Diese Seite drucken

Velleman DCM120 Bedienungsanleitung Seite 9

Messzange cat iii 600 v
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 54
9.2 DC VOLTAGE
range
200 mV
2 V
20 V
200 V
600 V
Impedance: 10 MΩ, max. input voltage: 600 V DC or AC rms
9.3 AC CURRENT
range
2 A
20 A
200 A
600 A
Frequency range: TRMS 40 Hz-1000 Hz
9.4 RESISTANCE
range
200 Ω
2 kΩ
20 kΩ
200 kΩ
2 MΩ
20 MΩ
Overload protection: 250 V DC or AC rms
V. 03 – 05/07/2019
Do not measure circuits that may contain voltages
resolution
0.001 V
Do not measure circuits that may contain voltages
resolution
0.001 A
Do not conduct resistance measurements on live circuits
resolution
0.001 kΩ
0.01 kΩ
0.001 MΩ
0.01 MΩ
DCM120
> 600 V AC or DC
0.1 mV
0.01 V
0.1 V
1 V
> 600 V AC or DC
0.01 A
0.1 A
1 A
0.1 Ω
0.1 kΩ
9
accuracy
± (0.5 % + 3)
± (0.8 % + 5)
± (1.0 % + 5)
accuracy
± (2.5 % + 10)
accuracy
± (1.0 % + 10)
± (0.8 % + 5)
± (2.0 % + 10)
©Velleman nv

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Dcm140

Inhaltsverzeichnis