Herunterladen Inhalt Inhalt Diese Seite drucken

Inhaltsverzeichnis - Desoutter Industrial E-LIT series Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 21
English
E-LIT BOX CONNECTIONS
5
6
4
J1: Power supply and digital
7
3
8
2
1
Pin
Name
no.
1
24 V
Power supply 24 V
2
0 V
Power supply 0 V
3
Common of inputs 1 to 4
4
Common of outputs 1 to 8
5
On pulse, the tool is locked
6
unlocked.
7
On pulse, the tool is
unlocked and the tool batch
counter is reset.
8
reverse mode.
Min. pulse duration: 100 ms
If other commands are required to
monitor the screwdriver, please refer to
the E-LIT PC software (minimum version
1.4)
5
4
6
J2: Digital outputs
3
7
8
1
2
Pin
Name
Description
no.
1
CC: the tool is sending a cycle
result for a correct tightening
operation.
2
CC: the tool is sending a cycle
result for a rejected tightening
operation.
3
CC: the tool is sending a cycle
result for a loosening operation.
01/2014
4
5
6
7
8
CC: contact closed
2
1
3
4
Pin
Name
no.
1
2
3
4
RD-
5 / 36
6159931280_05
CC: the tool is sending a cycle
result for a tightening operation
completed with a screw rotation
angle lower than expected.
CC: the tool has successfully
completed N correct tightening
operations.
CC: the tool indicates that the
cycle counter has exceeded the
maintenance threshold.
Refer to the tool user manual
for exact value and refer to the
E-LIT PC user manual to reset
the signal.
CC: the tool does not start if
trigger is pressed.
CC: the tool indicates that
counter batch has been
successfully reset.
J3: Ethernet network
Description
Reception -
Series: -

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Industrial e-lit box

Inhaltsverzeichnis