10.2 Troubleshooting

Problem
The machine
The plug is not connect-
does not
ed
switch on
The switch is not con-
nected
The emergency stop but-
ton is activated
The display is faulty
The machine
Faulty heating element
is not heating
Problem with the main
up
board
Temperature is set too
low
The heat-
Problem with the tem-
ing element
perature sensor
overheats
The timer
Disabled or faulty cylin-
does not
der sensor
count down
Problem with the elec-
tronic board
The press
The control buttons are
head does
not working
not lower
Leaking cylinder
Too low pressure on air
supply
The press
Faulty solenoid control
head does
valve
not come up
Leaking cylinder
The press
The timer is not counting
head stays
down
down after
No compressed air pro-
pressing
vided.
Description
CONTROL BOARD
MICA HEATING ELEMENT 400x500 2500W
TEMPERATURE PROBE
FUSE 5 x 20 mm T 16 A 250 V
CYLINDER Ø100 C50
AIR FILTER
SOLENOID CONTROL VALVE 5/2 G1/8 12V
FOAM 9.53 mm 400 x 500
TEFLON SHEET
Possible cause
Solution
Check your network and if the machine
is connected to it.
Set the main ON / OFF switch to 1.
Turn the red knob to unlock the emer-
gency stop button
Check that the cables are not dam-
aged (possible short circuit)
Check the connections and the condi-
tion of the wiring
Remove the heating element
Check the on-screen messages and
refer to the section error messages,
page 20-21
Check de messages on the LCD
screen, page 20-21
Contact your supplier
Check the connections
Check the on-screen messages and
refer to the section error messages,
page 20-21
Check the connections
Check the seals and all connections,
contact your supplier
Check the valve couplings, contact
your supplier for replacement
Check that the air supplied is above 3
bar
Check the valve couplings, contact
your supplier for replacement
Check the seals and all connections,
contact your supplier
See above