There are leaks in the vacuum cleaning network
- Check that the ducts are airtight
- Check that the vacuum inlets are not open, distorted or pulled out from
the wall
Carry out a duct
network test,
with all vacuum
inlets closed.
Adjusting the start-up sensitivity of the Central Unit :
Press and hold the OFF button until the maintenance LED lights up in green.
Release the OFF button, then press the ON button to make the maintenance LED flash
The number of flashes gives the current sensitivity setting on a 1 to 10 scale (the higher the
value the higher the sensitivity).
By default, the sensitivity is adjusted on 5.
Pressing the ON button increases sensitivity by one step.
Pressing the OFF button decreases sensitivity by one step.
In order to validate your choice, do not touch the buttons anymore and wait for 30 seconds,
letting the system record the new required parameters.
You now benefit from your new settings.
Carry out a duct network test:
FITTER'S ADJUSTMENTS
15