SAFETY TIPS

DO NOT submerge the unit in water
The product is not designed for use in medical evaluations. The product
can only be used to measure food temperature.
Only qualified personnel should perform repairs not covered in this manual.
FEATURES
Ultra Low power consumption in shutdown mode
Backlit LCD display
Laser On/Off switch
°C and °F selectable
Temperature data storage

SPECIFICATION

Distance Spot Ratio: 12:1
Temperature Range
Accuracy
Resolution
Response Time
Auto Power Off
Battery
Battery Life
Dimensions
Weight
UNIT DIAGRAMS
1. Unit
Display Screen
-50°C to 400°C (-58°F to 752°F)
±3°C (±5°F) from -50°C to -30°C (-58°F to -22°F)
±2°C (±3°F) from -30°C to 100°C (-22°F to 212°F)
±2% from 100°C to 400°C (212°F to 752°F)
0.1°C (0.1°F)
500ms
Automatically after approx 6 secs
9V
8.5hrs
180(H) x 50(W) x 100(D)mm (7.08"x1.97"x3.94")
225g
Laser Sighting
Measuring Window
Measuring Trigger
Battery and cover
2. Battery cover
/ ºF Switchable
ºC
Laser on/off
9V Battery
c
ON
F
OF