Herunterladen Inhalt Inhalt Diese Seite drucken

Frequenz- / Phasengang-Analysator Und Antennenanalysator; Technische Merkmale; Mehrkanal-Oszilloskop; Allgemeines - OSA103 Mini Bedienungsanleitung

Pc-basiertes usb-multifunktions-messgerät
Inhaltsverzeichnis

Werbung

Frequenz- / Phasengang-Analysator und Antennenanalysator

Die Pfeile nach oben / unten ändern den Bereich (Skala) des ersten Diagramms.
Strg + Pfeile nach oben / unten ändern den Bereich (Skala) der zweiten und dritten Grafik für AA. Strg +
Pfeil links / rechts Anzeige Horizontalzoom einstellen.
Mutually Exclusive Functions
Sync does not turn on (power button is not
active).
Generator virtual channel not displayed. Strobe mode enabled.
Scroll display mode not working.
Generates only sine wave (other forms
not present).
20,000 samples is set and FFT is in Auto
mode but FFT calculated only over 2048
samples.
Peak detector mode or averaging (Hi
Res) not activated.
The final frequency of the oscilloscope
synchronous frequency sweep of the
generator looks incorrect on the display.
RS232 protocol decoder not working. No
decoded data displayed.
When triggering activated, signal is not
synchronized.
Strobe mode does not turn on (the power
button is not active).

Technische Merkmale

Mehrkanal-Oszilloskop

Allgemeines

Anzahl der analogen Kanäle: 1 Anzahl der digitalen Kanäle: 4
Generator virtueller analoger Kanal.
Analoge Kanalbandbreite: 1 Hz ..... 400 MHz.
Maximale Abtastrate des analogen Kanals (Echtzeit): 200 MHz.
Maximale Abtastrate des digitalen Kanals (Echtzeit): 1,6 GHz.
Maximale Abtastfrequenz (für periodische Signale - Stroboskop): 10 GHz.
One of the following modes is enabled:
Frequency sweep mode generator in synch with
the sweep.
Frequency / phase meter.
Antenna analyzer mode.
Frequency sweep in synch with the oscilloscope
sweep is on.
10 M or 100 M frequency range selected (button
pressed).
Digital channels with sampling frequency of 1.6
GHz are turned on (so the number of analog
samples for FFT is 8 times less).
Fast sweep is turned on, the sampling frequency
is maximum (200 MHz) so these modes lose
their meaning.
Fast sweep is turned on and the signal takes
more than 10 divisions. "Scroll" horizontally to
the end of the display.
The sampling rate is too low (<4 * Baud Rate) or
too large (the entire scan is less than the
duration of one decoded byte). Change the
sweep speed.
Incorrect source, level, or trigger hysteresis
setting. Accidentally pressed button [T+] to
enable additional trigger modes.
Frequency sweep in synch with the oscilloscope
sweep is on.
49

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis