Herunterladen Inhalt Inhalt Diese Seite drucken

ECG ZZ 35 Bedienungsanleitung Seite 40

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Automatic regime
A sensor of temperature and humidity is installed in the appliance. By means of it, the appliance
is set up to an optimum humidity, and starts functioning in conformity with the room temperature
(surrounding temperature).
Surrounding temperature (degrees of Celsius)
The amount of steam is set up automatically based on the difference between the measured humidity
and the ideal one.
After filling the tank with water, the operation is started automatically after 2 – 5 minutes, irrespective
of the reading of the indicator WATER (the water needs 2 – 5 minutes to run down from the tank to
the suction slot, and the appliance does not function in the meantime).
Noiseless regime
Depress the push-button ON/OFF, and afterwards, during automatic operation, depress the push-
button SET UP (adjustment of regime) and select ZZZ
(Noiseless operation) in order to change to noiseless regime.
Ideal humidity in night regime is set up to 50 % and the
maximum operating time is 6 hours.
The heat generation of steam (indicated by the symbol
HEATING) is stopped after 6 hours.
Should the water run out from the tank during night regime,
there appears the symbol WATER and the humidifier is
switched off. (The acoustic advice of the shortage of water
does not sound.)
difference between ideal humidity of
50% and the actual one
>16
15 ~ 4
<3
Actual humidity is higher than the ideal one
Regime of personal adjustment
Switch on the appliance by depressing the push-button ON/OFF, and afterwards, depress the push-
button SET UP and change to regime of personal adjustment.
39
<19 °C
20 ~ 21 °C
22 ~ 24 °C
>25 °C
Ideal level of humidity
65%
60%
55%
50%
Steam generation
High output
Mean output
Low output
Stop