Herunterladen Inhalt Inhalt Diese Seite drucken

View In 1/ 2; View Out 1/ 2 / 3 - Monacor STA-1000DSP Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

8.3 View IN 1/2 (fig. 9)
Buttons to go to a different view
Curve diagram of the magnitude fre-
quency response
Each of the 10 parametric filters has a
point of reference (small square with fil-
ter number) and a frequency curve in a
specific colour. The frequency response
resulting from all active filters is repre-
sented by a white curve.
Some of the filter parameters can also
be set graphically. To do so, move the
corresponding point of reference with
the mouse:
– move horizontally to change the fre-
quency
– move vertically to change the gain
– move horizontally with the right mouse
button to change the quality factor/
bandwidth
– double-click a point of reference to
switch the corresponding filter on or off
to show/ hide the values of all active
filters
to switch the fine-adjustment mode
on and off
to enlarge the display ⇒ full-screen
mode;
to return to the reduced-
size mode
to save curves as image files (PNG)
Control GAIN to adjust the volume of the
corresponding input; the level indicator
is next to the control; the input / indication
field for the gain value is beneath the
control (same effect as
Switches ON to activate /deactivate the
corresponding filter
List field TYPE to select the filter type
8.4 View OUT 1/ 2 / 3 (fig. 10)
Buttons to go to a different view
Controls MIXER to adjust the mixed sig-
nal from the two input channels for this
output; the level indicators are next to
the controls; the input / indication fields
for the gain value are beneath the con-
trols
Curve diagram of the magnitude fre-
quency response
(description
chapter 8.3,
Control GAIN to adjust the volume of the
corresponding output; the level indicator
is next to the control; the input / indication
field for the gain value is beneath the
control (same effect as
Switches ON to activate / deactivate the
corresponding filter
20
View IN 1
Input / Indication field FREQ for the filter
frequency (enter values in Hz)
Input / Indication field Q / BW for the qual-
ity factor / bandwidth (click Q or BW to
change between quality factor and band-
width)
Input / Indication field GAIN for filter boost /
attenuation
High pass filter HPF: input / indication field
for the cut-off frequency (enter values in
Hz, "Off" < 20 Hz)
High pass filter HPF: list field to select
the filter type
Low pass filter LPF: input / indication field
)
for the cut-off frequency (enter values in
Hz, "Off" > 20 kHz)
Low pass filter LPF: list field to select the
filter type
)
)
View OUT 1
Switch MUTE to mute the correspond -
ing input (same effect as
)
Button COMPRESSOR to call up the
configuration window for the compres-
sor of the corresponding input (
ter 8.6)
Rotary knob DELAY with input / indica-
tion field for adjusting the signal delay of
the corresponding input; select the
measuring unit from the list field: time or
distance (for automatic calculation of the
sound delay time)
Level LIMITER: rotary knob THR with
input / indication field for the threshold
value
Level LIMITER: rotary knob REL with
input / ndication field for the release time
chap-

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis