External control potential free
This model is suitable for:
Ceiling lift 1060 (in all stroke lengths)
Ceiling lift 1070 (in all stroke lengths)
Ceiling lift 1090 (in all stroke lengths)
Ceiling lift 2040 (in all stroke lengths)
Ceiling lift 2050 (in all stroke lengths)
Ceiling lift 3040 (in all stroke lengths)
Ceiling lift 3050 (in all stroke lengths)
Ceiling lift 4050 (in all stroke lengths)
Ceiling lift PCL-2050 (in all stroke lengths)
Ceiling lift PCL-3050 (in all stroke lengths)
Ceiling lift PCL-4050 (in all stroke lengths)
Ceiling lift PCL-5050 (in all stroke lengths)
Down
261125
Up
Down
Up
Com
Direction keys
Earth
N
L
Mains In
Power Cord (260015)
230VAC 50-60Hz
partno. motor
partno. switches
260057
261084
260061
261085
260053
261085
260054
261084
260054
261084
260054
261084
260054
261084
260054
261084
261253
261085
261253
261085
261253
261085
261253
261085
External control
potential free
End switch "Down" (part no. depends on lift type)
Service
Down
Up
Endswitches
End switch "Up" (part no. depends on lift type)
Up
Down
Com
Earth
Motor
The brown and black wire are switched in the models 1060, 1070 and 1090
21
22
21
22
Lift motor 230VDC (part no. depends on lift type)