CONNECTING THE UNIT

CAUTION: A 5-micron filter (TSD800-6), not included, must be installed with the unit
to ensure proper air filtration.
1
2
Items
Description
1
To Air Source
2
Air Filter (Not included)
3
Power Adapter
4
Foot Switch
6

SETUP INSTRUCTIONS

Refer to Figure 1.0
6.1 Manual Dispense Cycle Setting:
1.
Turn on the unit by pressing the Power button (1).
2.
Press the Mode button (2) until "MANUAL MODE" appears on the
Display.
3.
Turn up the air pressure by rotating the Air pressure regulator knob (6)
until the desired pressure is indicated on the Air pressure gauge (5).
4.
After filling the barrel or using pre-packaged adhesive, attach syringe to
receiver head assembly. Make certain that the syringe locks into place.
5.
Connect the plug end of the receiver head assembly to one of the air
dispense outlet (7).
6.
If vacuum "suck back" is needed, rotate the Vacuum regulator (8)
counter clockwise until the desired vacuum pressure is obtained.
7.
Press and hold the Footswitch to activate dispensed cycle. (The Manual
Mode is now activated)
6.2 Automatic Dispense Cycle Setting
1.
Push the Mode button (2) to select "TIMED MODE".
2.
Press and hold the Set button (3) for two seconds to enter set up
screen. The last digit of the dispense time will be highlighted.
3.
Press the Set button (3) to move the cursor to the next position.
3
4
Figure 2.0
5
4.
Press the (+) and (-) button to set the time
5.
Press and hold the Set button (3) for two seconds to save the data.
6.
Depress Foot switch to activate timed dispensed cycle.

6.3 Cycle Counter

The cycle counter records the numbers of automatic dispense cycle being
activated. Up to 65,535 cycles can be recorded. This number is shown at
the lower right hand corner of the LCD. To reset the counter, press and
hold the Set button (3) for two seconds to enter the set mode. Then press
and hold the Set button (3) for four seconds to reset the counter.
7
OPERATION DIAGRAM
MODE
:Press then release
Prog
Time Counter
:Press and hold for approximately 4 seconds then release
POWER
MODE
SET
Normal Operation
OFF
TIMED MODE
P1
2.250
00004
Power ON/OFF
P1
SETUP MODE
P1
2.250
00004
P1
SETUP MODE
P1
2 .250
2
00004
P1
TIMED MODE
P1
2.251
00004
COUNTER RESET
SETUP MODE
P1
2
2 .251
00004
:Press and hold for approximately 2 seconds then release
TIMED MODE
P1
2.250
00004
MANUAL MODE
*************************
Change Mode
Setup
Time setting
TIMED MODE
2.250
00004
in TIMED MODE
SETUP MODE
SETUP MODE
2
2 .250
00004
P1
2 .250
2
00004
TIME SETTING
SETUP MODE
SETUP MODE
2 .251
2
00004
P1
2
2 .250
00004
SETUP MODE
Save and Exit...
P1
2 .251
2
00004
TIMED MODE
Save and Exit...
P1
2.251
00000
6