CONNECTING THE UNIT

CAUTION: A 5-micron filter (TSD800-6), not included, must be installed with the unit to
ensure proper air filtration.
1
2
Items
Description
1
To Air Source
2
Air Filter (Not included)
3
Power Adapter
4
Foot Switch
6

SETUP INSTRUCTIONS

Refer to Figure 1.0
6.1 Manual Dispense Cycle Setting:
1. Turn on the unit by pressing the Power button (1)
2. Press the Mode button (2) until "PURGE" appears on the Display.
3. Turn up the air pressure by rotating the Air pressure regulator knob (6) until
the desired pressure is indicated on the Air pressure gauge (5)
4. After filling the barrel or using pre-packaged adhesive, attach syringe to
receiver head assembly. Make certain that the syringe locks into place.
5. Connect the plug end of the receiver head assembly to one of the air
dispense outlet (7)
6. If vacuum "suck back" is needed, rotate the Vacuum regulator (8) counter
clockwise until the desired vacuum pressure is obtained
7. Press and hold the Foot switch to activate dispensed cycle. (The
Purge/Manual Mode is now activated)
6.2 Automatic Dispense Cycle Setting:
1. Push the Mode button (2) to select "TIMED" mode
2. Rotate the Time control knob (9) to set desired dispense time
3. Repeat step 3 to 6 in Section 6.1
4. Depress Foot switch to activate timed dispensed cycle
3
4
Figure 2.0
5

6.3 Cycle Counter

The cycle counter records the numbers of dispense cycle being activated. Up
to 65,535 cycles can be recorded. This number is shown at the lower right
hand corner of the LCD. Press the Counter Reset button (3) to clear the
counter.
7

TROUBLESHOOTING

PROBLEM
POSSIBLE CAUSE
LCD does not
No power input
light
System will not
Foot switch not
actuate
plugged in or
improperly plugged
in
Defective foot
switch
Broken wire or loose
connection inside
unit
Defective solenoid
Defective PC board
System will not
Insufficient air
pressurize
pressure
Air hoses not
plugged in
Regulator defective
System will not
Vacuum setting is
pull vacuum
too low
Defective solenoid
Defective vacuum
venturi
Defective vacuum
needle valve
Inconsistent
Air bubbles in
dispensing
adhesive
Dispense time is too
low
Dispense needle
started to clog
CORRECTION
Check power cord
connections
Turn on power
Check foot switch
connection
Foot switch needs to be
repaired or replaced
Unplug power cord and
disconnect air supply.
Remove cover and check
for broken wires or loose
connections
Replace solenoid
Replace PC board
Increase air supply
pressure
Check connection
Replace regulator
Increase vacuum setting
Replace solenoid valve
Replace venture
Replace needle valve
Reduce vacuum setting
Increase dispensing time
Replace needle
6