MOUNTING ON WALLS, SETUP ORDER
1. Before switching on for the first time carefully remove the packaging material taking care not to
damage the device or power cable. Do not use the product if damaged in any way! 2. The device
may only be used indoors in dry conditions! 3. For functioning the free flow of warm air must be
ensured, so choose the installation place on the wall according the figure 2.! It is forbidden to
place the device directly under a power outlet! 4. Drill 2 appropriately sized bore into the wall for
the dowels, at least a 180 cm above floor level, horizontally 52 cm apart from each other. 5. Place
the dowels into the bores, then with the included screws screw them in so the head of the screws
are 15 mm away from the surface of the device. 6. Place the bores on the back side of the device
on the screws, move it to the left as far as possible then lower it. Make sure the heater is stable on
the wall! 7. Connect the device to a standard grounded wall power outlet! 8. Place 1 CR2025
sized (3 V) lithium button battery in the remote control. Watch for the right polarity! With this the
device is operational.
Caution: Risk of electric shock! Do not attempt to disassemble of modify the unit or its
accessories. In case any part is damaged, immediately power off the unit and seek the
assistance of a specialist.
In the event that the power cable should become damaged, it should only be replaced by the
manufacturer, its service facility or similarly qualified personnel.
Meaning of symbol on appliance: Do not cover!
Covering the unit can cause overheating, fire or electric shock!
FEATURES
• wall mounted PTC* heater with fan, for warming the air in indoor spaces • adjustable output (1000 / 2000 W) • functions: cold-, warm-, hot air • switchable air flow control • inbuilt thermostat • protection from overheating
• 8 hour timer • combined LCD display • with remote control
STRUCTURE (figure 1.)
1. cold air entry port • 2. hot air exit port • 3. oscillating, air controlling lid • 4. ON/OFF switch (III) • 5. timer setting ( ) • 6. combined LCD display • 7. power cord • 8. fixing points• 9. screws, dowels
10. ON/OFF switch
• 11. Mode switch MODE • 12. Timer setting TIMER • 13. Air control switch OSCIL • 14. Temperature setting + (UP), - (DOWN) • 15. Delete CANCEL
OPERATION
The device can be operated with the remote control, or with the buttons on the control panel. After you connected it to the power grid, the device emits a short beep, and the combined LCD display will show the
actual temperature in °C.
The function of the (III) button on the device.
button press
1.
fan
2.
heater stage I (1000 W)
3.
heater stage II (2000 W)
4.
heater stage II (2000 W) + air flow control
5.
cooling (30 mp), shutdown
Until the device does not shut down on its own, do not unplug it, because that can damage the device! After shutdown the air flow controlling lid will close!
With the TIMER button on the remote control or the device the remaining operation time can be set, which can be set in 1 hour intervals till a maximum of 8 hours. If the TIMER function is active, it is shown on
the display with a clock icon. The TIMER setting will be deleted when the device shuts down.
With the
button on the remote control the device can be turned ON or OFF. With the MODE button the I, II heater stages, or the fan only mode can be chosen. With the OSCIL button the continuous air flow
control can be turned on, and the air flow control lid can be halted in its present position. With the + and – buttons the target reference temperature can be set or checked, which the device will show for 3
seconds after button press. The thermostat in the device will activate heater stage one if there is a 2 °C difference, and if a ≥ 4 °C difference is observed heater stage II. As soon as the configured temperature
is achieved the heater elements will turn off, the fan will further. The CANCEL button deletes the heater stage chosen by the thermostat, with the MODE button the previously chosen stage will be activated.
The overheating protection in the case of an overheating shuts down the device, e.g.: when the air entry or exit ports are covered. Unplug the device, by removing the power cord from the socket. Let the device
cool down (min 30 minutes). Make sure, that the air entry and exit ports are free, if necessary clean them. Setup the device again. If the overheating protection activates again, unplug the device by unplugging
the power cord and turn to a qualified service Centre.
CLEANING, AND MAINTENANCE
In order for the device to work properly, with a frequency depending on the severity of the contamination, but at least once a month the device should require cleaning.
1. Before cleaning turn OFF the device, then unplug it by removing the power cord from the socket!
2. Leave the device to cool (min. 30 minutes).
3. The air entry and exit ports are cleaned with a vacuum cleaner.
4. With a lightly moist cloth clean the outside of the device. Do not use aggressive cleaners! No liquid can go into the inside of the device or on the electric parts.

TROUBLESHOOTING

Malfunction
In heater mode the device does not heat up
overheat protection activates frequently
the device does not react to the remote controls signals
DISPOSING OF ALKALINE AND RECHARGEABLE BATTERIES
Batteries, whether alkaline or rechargeable, must not be handled together with regular household waste. It is the legal obligation of the product's user to dispose
of batteries at a nearby collection center or at a retail shop. This ensures that the batteries are ultimately neutralized in an environment-friendly way.
TECHNICAL SPECIFICATIONS
power supply:. . . . . . . . . . . . . . . . . . . . . . 230 V / 50 Hz
output: . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 / 2000 W
maximum output: . . . . . . . . . . . . . . . . . . . 2000 W
IP protection: . . . . . . . . . . . . . . . . . . . . . . IP20: Is not protected from entering liquids!
size of heater: . . . . . . . . . . . . . . . . . . . . . 66 x 16 x 17 cm
weight: . . . . . . . . . . . . . . . . . . . . . . . . . . . 3,5 kg
length of power cord: . . . . . . . . . . . . . . . . 1,6 m
noise level:. . . . . . . . . . . . . . . . . . . . . . . . 52 dB(A)
remote control power supply:. . . . . . . . . . 1 x CR2025 (3 V) battery, included
* The PTC (Positive Temperature Coefficient) is a ceramic polycrystalline semiconductor, combined with barium and titanium. Its main benefit is,
that it has a temperature self-regulating property, so there is no need for any cautionary measures for overheating protection,
and the device saves a substantial amount of energy.
activated function
Possible solution for the malfunction
check, the things mentioned in overheat protection
check the thermostat settings
clean the device
check the batteries in the remote control
ż