ELECTRONIC CONTROL PANEL
MAINTENANCE REMINDER
- Only available if the maintenance reminder function has been
activated and programmed by your supplier!
Once the maintenance interval is reached, the display will
intermittently show the message:
Maintenance Now
While the appliance will continue to operate normally,
it is recommended to have preventive maintenance
performed by a professional.
SERVICE MODE
In service mode the display shows the time of day and the
remaining capacity:
8:01
REGENERATION MODE
In regeneration mode the display shows the actual
regeneration cycle and, where relevant, the total
remaining regeneration time and remaining cycle time:
BRINE FILL
REGEN PENDING
Rgn:XXX CycY:ZZZ
The appliance can be reset to service mode at any time
by pressing the scroll
advancing it through the regeneration cycles.
CHECKING THE FLOW METER
In case of water usage, the remaining capacity counter
in the service display will count back per unit, i.e. per litre.
This way the correct functioning of the water meter
can be verified.
MANUAL REGENERATION
It is possible to manually initiate an immediate
regeneration or a delayed regeneration
(at the preprogrammed time of regeneration).
10
STEP 1. Press the scroll
show:
1000L -
button, as such manually
button; the display will
Regen in 10 sec
STEP 2. If the control panel is left in this position,
the countdown timer will countdown to 0 sec and start
an immediate regeneration.
To cancel this mode, press the scroll
the countdown timer has reached 0 sec; the display will
show:
Regen @
STEP 3. If the control panel is left in this position,
a delayed regeneration will be started at the indicated
preprogrammed time of regeneration.
To cancel this mode, press the scroll
the control panel will return to the service mode.
PROGRAMMING INSTRUCTIONS
(BASIC SETTINGS)
- Before entering the programming mode, make sure that the
appliance is in service mode.
- In case no button is pressed in a period of 5 min, the control
panel will automatically return to the service mode;
any changes made will NOT be saved!
STEP 1. Press the scroll
button and hold it for 2 sec
until the display shows:
Language:English
Press the up
or down
STEP 2. Press the scroll
button again; the display will
show:
Set time:
Press the up
or down
of day.
STEP 3. Press the scroll
button again; the display will
show:
HardUnit:
Press the up
or down
of measure for water hardness. Make sure it is identical
to the unit of measure of the water hardness test kit
or water analysis report that is used to determine
the hardness of the incoming untreated water!
button before
2:00
button,
button to set the language.
8:01
button to set the time
°f
button to set the unit

Werbung