START-UP

After the product has been ASSEMBLED and LEAK TESTING has been carried out
successfully, it is immediately ready for operation.
The product can be damaged if the gas cylinder is moved!
Entrained liquid phase can cause the pressure to increase in the LPG system and damage
the product or the LPG system.
Do not move the gas cylinder while the system is in operation.
A pressure regulator must be connected to the outlet side of the changeover
valve to reduce the nominal connection pressure of the consuming device.
We recommend:
Low pressure regulator
Type FL 90-4
Type FL 91-4
Type FL 92-4
For larger flow rates to 12kg/h we recommend this regulator:
Type BHK 052 (e.g. Part no. 05 298 00 or 05 299 00) or combination AUV with low pressure
regulator 50 mbar with OPSO (SAV) Part no. 05 087 03.
If LPG is withdrawn too quickly or is continuously withdrawn from the cylinder on
the operating side, the temperature of the gas falls and, as a result, the cylinder pressure
drops below the required inlet pressure of the regulator. LPG is then also withdrawn from the
reserve cylinder.
Proper operation of the system is no longer guaranteed.
The LPG cylinders on both sides may be emptied simultaneously or also at different rates.

OPERATION

Cylinder replacement during operation
1. Set the changeover device so that the arrow GREEN is pointing to the cylinder(s)
on the reserve side. (Always turn the rotary knob
2. Close the cylinder valve of the empty gas cylinder
2. Loosen the connections to the gas cylinder
4. Replace the empty cylinder with a full one and connect the full one.
The gas non-return valve prevents the gas flow from escaping through the free
connection
during cylinder replacement.
5. Open the cylinder valve.
6. Check for leaks.
7. The full cylinder is available as a reserve.
The gaskets at the inlet connections (if provided) must be replaced when re-assembling!
Make sure that the gaskets sit properly in the mounting and that the screws are tightened.
The LPG cylinder(s) must be upright when gas is being withdrawn.
Gas is withdrawn only from the gaseous phase.
The gas cylinder(s) must be secured so that it cannot topple over.
Protect gas cylinder(s) against radiant heat or heat from heating appliances.
Observe the installation regulations in the respective countries.
Artikel-Nr. 02 491 50 d
Safety equipment
with OPSO and PRV
with OPSO and PRV
with PRV
Part no.
05 004 00
05 104 00
01 004 00
as far as it will go to the reserve side.)
21 / 24

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis