Example of application:
Four-cylinder system to operate with large cylinders with remote display option
Low pressure regulator with safety overpressure shut-off valve (OPSO) and pressure relief
valve PRV, GS excess flow valve, automatic changeover valve type AUV with electronic
remote display sensor and hose lines and pipes upstream from the changeover valve.
Mounting material
Excessive force may damage the pressure regulator.
This can cause leaky connections.
Attachments must be dimensioned and connected with the base (construction) so that
this provides a secure hold on the one hand and enables forces to be deflected safely on
the other.
Forces should not affect on the pressure regulator.
Artikel-Nr. 02 491 50 d
Support rail option
Support rail, e.g. Part no. 02 510 00, for fixing
to a wall or another stable base with the
enclosed mounting material.