Connections could become leaky, if they are contaminated or corrupted
Therefore, the connections must regularly be checked for leak-tightness. Swap the product
where appropriate.
Keep all connections free from contamination, even small amounts of dirt can cause
connections to leak.

ASSEMBLY

Before assembly, check that the product is complete and has not suffered any damage during
transport. ASSEMBLY must be carried out by a specialised company.
See USER QUALIFICATION!
The specialised company and the operator must observe, comply with and understand all of
the following instructions in this assembly and operating manual. For the system to function
as intended, it must be installed professionally in compliance with the technical rules
applicable to the planning, construction and operation of the entire system.
Metal chips may cause eye injuries.
Wear safety goggles!
Malfunctions caused by residues! Proper functioning is not guaranteed.
Visually check that there are no metal chips or other residues in the connections!
It is important that metal chips or other residues are blown out!
Install with suitable tools, if required.
Regarding screw connections, use a second spanner to brace against the connection nozzle.
Do not use unsuitable tools, such as pliers.
Product damaged through incorrect installation direction
Proper functioning is not guaranteed.
Observe the installation direction (marked on the product with an arrow
Screw connections
If connections leak, there is a danger of explosion, fire or suffocation!
Gas may escape if the product is turned.
Do not turn the product after it has been installed and the connections have been
tightened.
Tighten connections only when they are not pressurised.
Consider installation location and installation position (see instructions on INTENDED USE).
The gaskets at the inlet connections (if provided) must be replaced when re-assembling!
Make sure that the gaskets sit properly in the mounting and that the screws are tightened.
Connecting and installing hoses assemblies
Connect hoses so that mechanical, thermal and chemical stresses are avoided:
 mechanical stress: e.g. do not pull the hose assembly over sharp edges
 thermal effect: e.g. avoid open flames, radiant heat
 chemical effect: e.g. avoid grease, oil, caustic substances
Install hose assemblies so that they are not under tension (no bending and tensile strains or
torsion).
Install hose assemblies so that their connections cannot loosen unintentionally.
Connections to the pressure regulator with 90° outlet prevent the hose assembly from being
kinked.
Observe the applicable national installation regulations for LPG systems.
Suitable high-pressure hoses must be used for connection to the gas cylinders.