Figure 2:
P Open the release valve by turning it anticlockwise (to the left).
P Close the release valve by turning it clockwise (to the right).
Figure 3:
a Load
b Loading cup
Care and maintenance of the jack...
1. When the jack is not in use, the lifting arm and the socket are to be moved fully down so that the
piston rod and pin are protected from corrosion.
2. The jack will work best when filled with hydraulic jack oil with a viscosity of SAE 10.
3. Always clean the jack thorougly and grease all the external parts well.
P
P
P
P P P P
Tegro 10006 Bedienung.indd 10
G
P P
P
P
P P
P
8

Fault finding

Dealing with problems

If there is too little oil in the jack: Remove the covering plate 5,
undo the blind plug 4 and then replenish the oil reservoir with
appropriate hydraulic jack oil.
To de-aerate the hydraulic cylinder, remove the covering plate 5
and undo the blind plug 4.
The jack could have an air lock.
Open the release valve 1 one full turn. Bring the jack into the
vertical position by raising the rear wheels from the ground.
Move the handle forcefully up and down.
Close the release valve again and operate the jack.
The valves are probably not fully closed.
Lower the lifting arm and close the release valve.
With one foot on a front wheel, pull the lifting arm upwards by
hand. Open the release valve again and lower the lifting arm.
The jack should now be ready for use again.
The lifting arm return spring is probably broken or has become
detached.
Replace or re-attach the lifting arm return spring and grease it.
Clean and oil all moving parts on the lifting mechanism.