Herunterladen Inhalt Inhalt Diese Seite drucken

Safety Information; Electrical Connection; Dry Installation - Oase Aquamax Dry 8000 Serie Gebrauchsanweisung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
- GB -
Use other than that intended
Danger to persons can emanate from this unit if it is not used in accordance with the intended use and in the case of
misuse. If used for purposes other than that intended, our warranty and operating permit will become null and void.
Pos: 31 /Alle Produkte/CE-Herstellererklärung Pumpen @ 0\mod_1125572816203_121.doc @ 1191
CE Manufacturer's Declaration
We declare conformity in the sense of the EC directive, EMC directive (89/336/EEC) as well as the low voltage direc-
tive (73/23/EEC). The following harmonised standards apply:
Pos: 32 /Pumpen/Schlammsauger/Alle Pumpen/Schlammsauger/EN-Normen Pumpen/Schlammsauger @ 0\mod_1126880686869_0.doc @ 5718
EN 60335-1, EN 60335-2-41, EN 55014-2, EN 61000-3-2, EN 61000-3-3
Pos: 33 /Alle Produkte/Unterschrift Hanke @ 0\mod_1126881079296_121.doc @ 5743
Pos: 34 /Alle Produkte/Sicherheitshinweise @ 6\mod_1174479103986_121.doc @ 33733

Safety information

OASE has manufactured this unit according to the current state of the art and the valid safety regulations. Despite the
above, hazards for persons and assets can emanate from this unit if it is used in an improper manner or not in accor-
dance with its intended use, or if the safety instructions are ignored.
For safety reasons, children and young persons under 16 years of age as well as persons who cannot recog-
nise possible danger or who are not familiar with these operating instructions, are not permitted to use the
unit!
Pos: 35 /Pumpen/Schlammsauger/Alle Pumpen/Schlammsauger/Die Kombination von Wasser und Elek. Pumpen @ 0\mod_1127161195057_121.doc @ 5848
The combination of water and electricity can lead to danger to life and limb, if the unit is incorrectly connected or
misused. Only operate the unit if no persons are in the water! Prior to reaching into the water, always disconnect the
power supply to all units used in the water. Compare the electrical values of the power supply with those on the type
plate on the packaging or on the unit itself. Ensure that the unit is fused for a rated residual current of max. 30 mA via a
residual current-operating system. Only operate the unit when plugged into a correctly fitted socket. Keep the power
plug and all connection points dry! Protect the connection cable when burying to avoid damage. Only use cables
approved for outside use. Do not carry or pull the unit by the connection cable! The power connection cable of this unit
cannot be replaced. If the cable is damaged, the entire unit has to be disposed of. Electrical installations at garden
ponds must meet the international and national regulations valid for installers. Never open the unit housing or its
attendant components, unless this is explicitly mentioned in the operating instructions. Never carry out technical
changes to the unit. Only use original spare parts and accessories for the unit. Only allow authorised customer service
outlets to perform repairs. Never run the unit without water! Never use the pump for fluids other than water! For your
own safety, consult a qualified electrician when you have questions or encounter problems!
Pos: 36 /Pumpen/Schlammsauger/Aquamax ECO/Elektrischer Anschluss Aquamax ECO @ 0\mod_1126270337051_121.doc @ 3961

Electrical connection

Only entrust an authorised expert to carry out the electrical connection in accordance with the German EVU and VDE.
VDE 0100 Part 702 is valid for all installations. Refer to the type plate for all capacity parameters. Only perform any
work on the unit when isolated!
Pos: 37 /Pumpen/Schlammsauger/Aquamax Dry/Getaucht aufstellen Aquamax Dry @ 6\mod_1190199003105_121.doc @ 38743
Submersed installation
Attention! Risk of damage! Ensure that the unit does not take in air or run dry.
Cut the stepped hose adapter to suit the hose diameter and screw onto the return. Place the unit horizontally with its
feet downward.
Pos: 38 /Pumpen/Schlammsauger/Aquamax Dry/Trocken aufstellen Aquamax Dry @ 6\mod_1190199200407_121.doc @ 38769

Dry installation

Attention! Risk of damage! Ensure that the unit does not take in air or run dry. Do not connect the unit to a
water line.
Cut both stepped hose adapters to suit the hose diameters, then screw each adapter on the intake (front) and return
(top). Place the unit horizontally with its feet downward. To prevent air from being taken in, ensure that unit and supply
hose are always 20 cm below the water level.
Pos: 39 /Pumpen/Schlammsauger/Aquamax Dry/Einschalten, Inbetriebnahme Aquamax Dry @ 6\mod_1190199413008_121.doc @ 38795
Switching on, starting up
Attention! Dangerous electrical voltage.
Possible consequences: Death or severe injury.
Protective measures: Disconnect the power plug prior to reaching into the water and commencing
work.
The unit switches on automatically when connection to the power supply is established. The power supply must be
disconnected to switch off the unit. The unit can be electronically controlled with the OASE garden outlet InScenio FM-
Master 3.
Pos: 40 /Pumpen/Schlammsauger/Aquamax Dry/Reinigung und Wartung Aquamax Dry @ 6\mod_1190199980828_121.doc @ 38821
6
Signature:

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Aquamax dry 14000 serie

Inhaltsverzeichnis