Emptying the coffee grounds collector, coffee drawer and the
drip tray
The drip tray collects the used water and the coffee grounds collector collects the used
coffee grounds.
The coffee drawer allows you to remove any coffee grounds below the percolation chamber.
If the message "Empty the two trays" is displayed, empty and clean
the drip tray.
1. Remove, empty and clean the coffee grounds collector. Fig. 21.
2. Remove the coffee drawer. Fig. 21.
Clean under water and dry well before refitting. Fig. 22.
First position the coffee drawer then the coffee grounds collector Fig.
23.
The drip tray is equipped with a float indicating when it requires emp-
tying. Fig. 24.
Circuit rinsing
You can perform a rinse at any time by pressing Prog then maintenance. Depending on the
types of recipes prepared, the machine can perform an automatic rinse when switching off.
Caution: during this rinse operation, hot water exits the coffee spout. Make sure the drip
!
tray is always in place even when the machine is not in use. Take care not to
burn yourself. The cycle only lasts a few seconds and will stop automatically.
Automatic clean programmes
Automatic clean programme for the coffee circuit
The machine will tell you when a clean programme is required. This clean must take place
every 360 preparations approximately.
To perform the clean programme, you will need a container with a capacity of at least 0.6 l;
this should be placed under the coffee outlets and a KRUPS cleaning tablet (XS3000).
Follow the instructions on-screen. It is also possible to launch cleaning via the maintenance
menu.
Important: you do not have to perform the clean programme immediately when the
!
appliance requests this; however, you should do this as soon as possible. If
cleaning is delayed, an alert message
operation is performed. You should only use KRUPS cleaning tablets (XS
3000), as the guarantee does not cover material damage caused by the use
of other brand tablets. The cleaning tablets are available from your KRUPS
After-Sales Service.
Caution: the cleaning cycle must be completed to comply with the guarantee condi-
!
tions.
The automatic clean programme includes two phases: a clean and a rinse cycle; the
programme takes about 13 minutes.
GENERAL MAINTENANCE
will remain on the screen until the