an "exempt" appliance ("exempted" from the controls which generally apply in the smoke control
area).
In England appliances are exempted by publication on a list by the Secretary of State in accor-
dance with changes made to sections 20 and 21 of the Clean Air Act 1993 by section 15 of the
Deregulation Act 2015. Similarly in Scotland appliances are exempted by publication on a list by
Scottish Ministers under section 50 of the Regulatory Reform (Scotland) Act 2014.
In Wales and Northern Ireland these are authorised by regulations made by Welsh Ministers and
by the Department of the Environment respectively.
Further information on the requirements of the Clean Air Act can be found here: https://www.
gov.uk/smoke-control-area-rules
Your local authority is responsible for implementing the Clean Air Act 1993 including designation
and supervision of smoke control areas and you can contact them for details of Clean Air Act
requirements"
"The TT30, TT30G, TT30S, TT30GS has been recommended as suitable for use in smoke control
areas when burning wood."

HEALTH AND SAFETY PRECAUTIONS

Special care must be taken when installing the stove such that the requirements of the Health
and Safety at Work Act are met.
Handling
Adequate facilities must be available for loading, unloading and site handling.
Fire Cement
skin. In case of contact wash immediately with plenty of water.
Asbestos
This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course
of installation then please seek specialist guidance and use appropriate protective equipment.
Metal Parts
When installing or servicing this stove care should be taken to avoid the possibility of personal
injury.
STOVE PERFORMANCE
Please refer to the table in the main instruction manual for details of the stoves' performances
PREPARATORY WORK AND SAFETY CHECKS
IMPORTANT WARNING
This stove must not be installed into a chimney that serves any other heating appliance.
stove to emit fumes into the room.
Chimney
adequate draught of approximately 15 Pa so as to clear the products of combustion and prevent
smoke problems into the room.
NOTE: A chimney height of not less than 4.5 metres measured vertically from the outlet of the
stove to the top of the chimney should be satisfactory. Alternatively the calculation procedure
given in EN 13384-1 may be used as the basis for deciding whether a particular chimney design
The outlet from the chimney should be above the roof of the building in accordance with the pro-
visions of Building Regulations
Some types of fire cement are caustic and should not be allowed to come into contact with the
Approved Document J.
If installation is into an existing chimney then it must be sound and have no cracks or other faults
which might allow fumes into the house. Older properties, especially, may have chimney faults or
the cross section may be too large i.e. more than 230 mm x 230 mm. Remedial action should be
taken, if required, seeking expert advice, if necessary. If it is found necessary to line the chimney
proved Document J.
Any existing chimney must be clear of obstruction and have been swept clean immediately before
There must not be an extractor fan fitted in the same room as the stove as this can cause the
27
In order for the stove to perform satisfactorily the chimney height must be sufficient to ensure an
will provide sufficient draught.
then a flue liner suitable for solid fuel must be used in accordance with Building Regulations Ap-
installation of the stove. If the stove is fitted in place of an open fire then the chimney should be swept