Direct intervention by the customer
In order to avoid unnecessary costs, ensure that the problem occurring in the machine is not included in the following
table before calling the servicing department.
DEFECT
The appliance does not function and the
indicator light (10) is off.
The appliance does not work and the
indicator light (10) is on.
The appliance functions correctly but
ground coffee is not dispensed.
11. Malfunctions – Faults
CAUSE
No electricity.
Coffee hopper (2) not placed properly.
Thermal protector has cut in.
Coffee beans receptacle gate (3) closed
10 EN
REMEDY
Check that the electricity is on.
Check the position of the mains switch
(11).
Reposition the hopper (2) so that it closes
the safety switch.
Wait until the appliance has cooled down.
Push the gate (3) towards the inside to
open the passage of the coffee to the
grinder.