GHV 1200-85/204 House Distribution Amplifier /
Hausanschlussverstärker
DOCSIS 3.1

2. Installation

2.1 Safety precautions

BEWARE:
You must adhere to the Safety Precautions of EN 60728-11 for installation
Before you start working on the installation, turn off Mains Power to the circuit.
Only let an authorized Electrician do the Mains power plug installation if needed.
Never do Installation or repair during thunder Storms.
Always connect the network by use of the Grounding Terminal of the device (with a copper wire
(diameter min. 4 mm2) to the Building Grounding Terminal!
Before you start working on the installation, turn off Mains Power to the circuit!
Observe the safety precautions!

2.2 Local setup

Mount the Amplifier.
Horizontal, free on the wall and so that the convection cooling of the unit
is not constrained.
On non-flammable material (Concrete or Brick Wall)
In a dust free environment, protected against moisture and fluid.
(Drop– and spray water)
Not in a spot with direct Sun radiation (e.g.. On the Roof)
Not directly along with Heat Sources (e.g. Heating Room)
In compliance with the highest allowed working Temperature
(measured at the Airflow under the Amplifier))

2.3 Wall mounting

Fasten the Amplifier according to its measurements (See Fig. 1.) on the wall.
(Screws-ø max. 4.8 mm, Distance between holes 158 mm)
Create a Grounding potential using the screw A and a sufficient fitted and stable copper cable
(diameter min. 4 mm2)
Connect the RF-Input B and the RF-Output C. Make sure you get perfect
connection between Coax cable and Connector.
Turn on the Mains Power to the circuit again.