Switching function (ON/AUTO/OFF) 7
AUTO: motion sensor works automatically in accordance
with the preset values.
D
ON: motion sensor is switched on for a maximum of 2
hours (constant light). After 2 hours, the motion sensor
switches back to AUTO mode. Even if the sliding switch
is still on the ON position. To switch on constant light
GB
again, switch the sliding switch from ON to OFF or AUTO
and then switch it to ON once more.
OFF: motion sensor is permanently switched off.
NL
Setting the twilight threshold
Carefully open the front cap.
Set the sliding switch 7 to the AUTO position.
F
► Motion sensor with manually set brightness value:
Set the desired brightness value 8 with the
adjustment screw, which is infinitely adjustable,
I
from 5 to 100.
Adjustment screw to the stop on the right side
(100) means: day operation. Adjustment screw to
P
the stop on the left side (5) means: night operation.
► Motion sensor with saved ambient brightness value:
To automatically program the ambient bright-
ness, set the sliding switch 7 to the AUTO
20
position. The time setting 9 may not be in the
„test" position!
Set the adjustment screw 8 to the position
for at least 1 second, thus activating the automatic
brightness detection.
„As soon as the ambient brightness corresponds to the
brightness that should be saved, switch the adjustment
screw 8 from the position
sition."
verändern." The LED  in the sensor area
begins to blink for 10 seconds.
The ambient brightness is saved. Consumers and the
LED  are then switched on for 5 seconds and then
completely switched off. The programming procedure
is finished.
Repeat the programming procedure above, if another
ambient brightness is to be saved.
Repeat the programming procedure after a loss of po-
wer.
„If the motion sensor is to use the programmed bright-
ness value as a reference value for the twilight threshold
after the completion of the programming procedure, re-
set the adjustment screw to position."
Setting the duty cycle (switch-off delay)
Carefully open the front cap, set the sliding switch 7 to
the AUTO position.
directly to the po-
.