SOLAR MODULE:
The solar panel effectively prevents the built-in battery from
discharging.
To ensure that this works, position the Power Station in a place that
provides sufficient light. This can be checked with the charging
indicator
. If the indicator does not light up, there is too little light
available.
Please remove all electricity consuming devices so as not to impede the
charge maintenance function..
Attention: The solar panel serves only to maintain the charge i.e.
the current battery status may be maintained but the battery cannot
be charged.
JUMP START AID:
1. SWITCH OFF the ignition. Switch off all accessories such as lights,
radios, air conditioning etc.
2. Make sure that all the switches on the jump start system are set to
OFF.
3. Connect the red ( + ) terminal clamp securely to the positive battery
terminal of the vehicle battery ( + ).
4. Do not connect either clamp to the negative terminal. Connect the
black (-) terminal clamp to a fixed metal part of the vehicle.
5. Switch the main switch
6. Start the vehicle. If the vehicle does not start, wait 3 minutes before
trying to start it again. (If this waiting period is not observed, this may
lead to damage to the jump start system).
7. Once the vehicle has been started, switch the main switch
and remove the black negative terminal clamp and then the red
positive terminal clamp.
Attention: The Power Station is fitted with a polarity indicator. If the
electrical connection is made correctly then the indicator
up green. If the connection is wrong, a warning note sounds and the
indicator lights up red.
AIR COMPRESSOR:
1. Open the cover
on the back of the Power Center and pull out the air
hose. Ensure that the nozzle lever is pointing UPWARDS.
2. Attach the valve adapter to the tyre valve stem and press down the
valve adapter lever so that it latches.
3. Set the compressor switch
4. Monitor the manometer
5. Once the desired pressure has been reached, set the compressor to
"off" (14) and remove the hose.
12-VOLT DIRECT CURRENT ELECTRICAL CONNECTION
Important: The 12-Volt direct current electrical connections
designed for 10 Amps. Do not connect any device(s) that need(s)
a stronger current to operate. .
1. Remove the cover of the 12-Volt socket
2. Put the 12-Volt accessory part into the socket.
3. Set the toggle switch º of the 12-Volt direct current socket to ON.
4. SWITCH ON the electricity and operate the 12-Volt device.
USB ELECTRICAL CONNECTION
Important: Before connecting the accessory make sure that the On/Off
switch ¸ of the USB connector is set to "off." Accessory connection
(MP3 players, mobile telephones etc.)
1. Connect the USB interface cable (included in the accessories) to the
accessory and to the USB connector of the portable Power Center.
2. Set the On/Off switch ¸ of the USB connector to "USB on." SWITCH
ON the accessory. (Before operating the USB device please ensure that
it is suitable for this)
INSTRUCTIONS ON CORRECTING FAULTS:
Fault
Insufficient power output
27.05.2010
14:42 Uhr
to "on."
to "off"
on the front module to "on."
during pumping up.
are
.
Cause
1. Power Station voltage is under 12 volts.
2. Too much power is being taken from the device
operated.
3. The inverter fuse ¹ is burnt through.
Seite 7
200 WATT / 230 Volt INVERTER
1. Before starting the inverter make sure that the switch ¸ is set to
"off."
2. Before connecting a 230 V device make sure that the device to be
connected is switched off and that the device has a maximum output
of 200 Watt.
3. Put the device's electrical plug into the inverter connector µ.
4. Set the inverter switch ¸ to "Inverter on". If the inverter is working
perfectly, the inverter power indicator display lights up green. Now
SWITCH ON the connected device. If the inverter power indicator
display lights up red and/or a warning sounds, switch off the inverter
immediately.
The possible causes of malfunction might be:
• Power Station battery too weak (check with key ¾)
• Inverter overloaded (wait 5 minutes for it to cool down)
• Connected device has output higher than 200 Watt.
TAKE CARE:
Some rechargeable devices are equipped with a separate charger
that can be connected to this alternating current inverter connector.
However, certain rechargeable devices are manufactured with built-in
chargers. (See the device manufacturer's manual). This category of
device may lead to internal damage to inverters and should not be
used with this inverter. During the first 15 minutes when the device is
operating, the temperature of the device must be monitored.
An unusually high temperature of the device is a sign that such devices
should not be used with this inverter.
LED WORK LIGHT
1. The LED work light
can be switched on and off by pressing the
lens.
2. The LED work light may be removed and attached to metal surfaces
lights
by means of its magnetic base. (Please use a clean handkerchief
between the LED work light and the surface as protection against
scratching).
3. The LED work light is equipped with an orange warning light. This can
be switched on and off with the side toggle switch. (Do not use the
warning light in an StVZO [Road Traffic Licensing Order] context).
4. The LED work light may be charged at any 12-Volt socket with the
charging cable.

SPECIFICATIONS:

Built-in battery:
15. Compressor output:
10. Inverter output:
4. 12-Volt electricity connector output:
5. USB electrical connector output:
6. Solar module output:
Charging connector outputs:
Battery built in:
Charging connector
:
Power maintenance:
Power connection outputs:
Vehicle charging socket
Alternating current socket µ:
USB socket
:
Jump lead
:
LED magnetic torch
:
Fuse:
DISPOSAL: Once it has reached the end of its useful life, do not dispose
of this product in the household waste but at the points set up for the
return of used electrical devices.
CLEANING: Clean the impact wrench housing as necessary with
a slightly damp cloth. Do not use any corrosive cleaning agents.
Correction
1. Recharge the Power Center immediately.
2. Reduce the load to 200 Watt at the most.
3. SWITCH OFF the device and the Inverter.
Disconnect the device.
Replace the fuse with a new one with a 25 Amp
rating. Replacing the fuse:
REMOVE the fuse with long-nosed pliers and
replace it with a new 25 Amp fuse.
12 Volt rechargeable sealed
lead battery / 12 Ah
260 PSI
200 Watt
12 Volt 10 A max.
5 Volt 500 mA
ca. 2 W / 110 mA
12 V / 12 Ah rechargeable
• 12 V / max. 2 A vehicle charging
cable. (Do not charge whilst travelling)
• 12 V / 500 mA plug mains connector
Solar panel: about 2 W / 110 mA
:
12 V
/ max. 10 A
230 V ~ / 10 A / 200 W
5 V
/ 500 mA
12 V / 8 mm
2
LED class 1
25 A flat blade fuse