Herunterladen Inhalt Inhalt Diese Seite drucken

Operation; Specifications - Monacor TVSET-400 Bedienungsanleitung

Video-überwachungssystem
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1

6 Operation

After all connections have been made, switch on the
switch-over unit with the POWER switch (5). The
channel display (1) lights up, and the operating mode
AUTO is activated.
If the surveillance system will not be used for a
longer period of time, disconnect the power supply unit
from the mains socket as it continuously has a low
power consumption (even with the switch-over unit
switched off).
6.1 Manual camera selection
For manual selection of a camera picture press the
button (11) on the remote control corresponding to the
camera connection. The channel display switches to
the number of the selected channel, and the picture of
this camera appears on the connected monitor.
6.2 Operating mode AUTO
In case of the operating mode AUTO all camera pic-
tures are switched in a cyclical sequence. The chan-
nels where no video signal is present are automatically
skipped. This operating mode is switched on with the
AUTO button (8) on the remote control.
6.3 Operating mode SCAN
In the operating mode SCAN camera channels which
have been selected before are switched in a cyclical
sequence. After switching-on, these are the channels
CH1 to CH4 (factory setting). This order can be chang-
ed as follows:
1) Press the PRGM button (10):
the channel display (1) shows "P".
2) Press the SCAN button (7):
the channel display shows "c".
3) Via the buttons "1", "2", "3", and "4" (6) enter the
desired order (max. 4 steps).
4) Press the PRGM button (10):
the channel display (1) shows "-" and changes
to the present channel number again after approx.
3 s.
5) If another operating mode was selected before,
press the SCAN button (7) to have the programmed
sequence running.
Note: A programmed sequence is not stored when
switching off the switch-over unit. After switching on
again, the factory setting (1, 2, 3, 4) is adjusted as
before.
6.4 Adjustment of the dwell time
The dwell time, i. e. the time until the next sequential
switching, is preset to 10 s after switching on. It can be
changed as follows:
1) Press the PRGM button (10):
the channel display (1) shows "P".
2) Press the DWELL button (9):
the channel display shows "d".
3) Via the numerical keys (6) enter the desired time
(1 – 99 s). When entering "0", a time of approx.
0.5 s is adjusted.
4) Press the PRGM button (10):
the channel display shows "-" and changes to
the present channel number after approx. 3 s.
Note: A changed dwell time is not stored when switch-
ing off the switch-over unit. After switching on again,
the time is 10 s as before.

7 Specifications

Camera (TVCCD-520)
Protective class of housing: . IP44
Image sensor: . . . . . . . . . . . 8.5 mm (
Number of pixels
horizontal: . . . . . . . . . . . . 384
vertical: . . . . . . . . . . . . . . 287
Resolution: . . . . . . . . . . . . . . 240 lines
Lens: . . . . . . . . . . . . . . . . . . 1 : 2.0/3.9 mm
Minimum illumination: . . . . . 0.5 lux
Infrared illumination: . . . . . . 6 IR light diodes
S/N ratio: . . . . . . . . . . . . . . . > 46 dB
Signal size: . . . . . . . . . . . . . CCIR
Power supply: . . . . . . . . . . . 12 V /50 mA via the
Ambient temperature: . . . . . 0 – 40 °C
Connection cable: . . . . . . . . 20 m with 9-pole mini
Dimensions: . . . . . . . . . . . . . 65 x 75 x 80 mm
Weight: . . . . . . . . . . . . . . . . . 68 g
Switch-over unit
Camera connections: . . . . . . 4 x 9-pole mini DIN jack
Audio/video ouptuts: . . . . . . 9-pole mini DIN jack
Video level: . . . . . . . . . . . . . 1 Vpp/75 Ω
Audio level: . . . . . . . . . . . . . max. 500 mV at 50 kΩ
Power supply: . . . . . . . . . . . 12 V /500 mA via sup-
Ambient temperature: . . . . . 0 – 40 °C
Dimensions (W x H x D): . . . 170 x 40 x 130 mm
Weight
switch-over unit: . . . . . . . . 240 g
remote control: . . . . . . . . . 30 g
According to the manufacturer.
Subject to change.
1
/
") CMOS
3
625 lines
50 single frames/s
switch-over unit
DIN plug
with supplied adapter
cable (1.7 m) to phono
plug
plied power supply unit
at 230 V~/50 Hz/10 VA
GB
9

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis