4. Cleaning and maintenance

Lid and toilet seat, control dials
EN
Clean the lid, toilet seat and control knobs every day using a soft cloth and warm
water with a mild household cleaner. Do not use abrasive, chlorine-based or
acidic cleaning products.
When cleaning the ceramic, always open the lid or remove it completely so that
any rising vapours cannot damage the plastic.
Toilet ceramic
Clean the ceramic regularly or as soon as it gets dirty. Use a commercial sanitary
cleaner to regularly clean the ceramic. To remove limescale, use a commercial
limescale remover or a vinegar-based cleaner. Always follow the manufacturer's
instructions when using a cleaning product.
Avoid any contact with hard or metal objects which could damage or mark the
surface.
Shower arm
ƒ Slightly turn the right rotary knob (A) to self-cleaning: The shower arm does
not extend and the water rinses the shower arm and cleans it in this position.
ƒ In the event of stubborn soiling, turn the right rotary knob until the shower
arm (C) extends with a small jet of water. Remove the dirt with the aid of a
suitable brush or a soft cloth. Only use a mild cleaning detergent when doing
so.
If using water with a very high lime content, lime deposit can build up on the
shower nozzle, shower arm and the safety and hygiene system. This can be
removed with a commercial limescale remover or vinegar-based cleaner, or
replaced in the event of more persistent deposits. These components are availa-
ble as spare parts (see "Spare parts" section).
16
5. Troubleshooting
The TECEone has been built in such a way that problems are extremely unlikely
and may only occur in very few cases. However, if a fault should occur, it is gen-
erally best to contact a suitable specialist (i.e. fitter).
Problem
Possible cause
Water is running/dripping out
of the ceramic.
The shower nozzle does not
The water pressure is too
extend.
low.
The shower jet is too weak.
The water supply hose is
bent.
The shower nozzle or
shower arm is blocked/cal-
cified.
No water comes out of the
The water supply has been
shower arm.
switched off.
The temperature of the water
The temperature cartridge
is suddenly too high or too
is faulty.
low.
Position of corner valves:
EN
Solution
Close the corner valve (see
illustration below) or the main
valve and call the fitter.
Call the fitter.
Call the fitter.
Clean the shower nozzle or
arm with a suitable brush or
replace it in case of limescale.
Check whether or not the
corner valves are turned (see
illustration below) or check
the central water feed supply.
Call the fitter.