ERROR opens the relay contacts when
an error condition occurs.
ERROR closes the relay contacts
when an error condition occurs.

SWITCH SW3

This switch enables normally open
and normally closed options to be
selected for skip and status.
The interface is factory set to option 1.
IMPORTANT
Care must be taken to ensure
correct connections to terminals.
NOTE
All relay contacts return to an
open circuit condition when power
is removed from the MI 12.
KEY
N/O Normally open.
N/C Normally closed.
Switch must be in
position shown.
Switch can be in either
position.
Bleeper on/bleeper off.
Factory set to bleeper on.
OPTION
TERMINALS
14 & 15
see page 1-11
PROBE
1
STATUS
N/O
SKIP
N/C
2
SKIP
3
N/O
PROBE
4
STATUS
N/O
PROBE
5
STATUS
N/O
TERMINALS
23 & 24
see page 1-11
1 2 3 4
PROBE
STATUS
N/C
A B C D
1 2 3 4
PROBE
STATUS
N/C
A B C D
1 2 3 4
PROBE
STATUS
N/C
A B C D
1 2 3 4
SKIP
N/C
A B C D
1 2 3 4
SKIP
N/O
A B C D
1-9