4-6. TEST RUN
• Be sure to perform the test run for each unit. Make sure each indoor
unit operates properly following the installation manual attached to the
unit.
• If you perform the test run for all indoor units at once, you cannot de-
tect any erroneous connection, if any, of the refrigerant pipes and the
indoor/outdoor unit connecting wires.
Make sure that the following is done.
• Power is supplied to the unit.
• Stop valves are open.
About the restart protective mechanism
Once the compressor stops, the restart preventive device operates so the
compressor will not operate for 3 minutes to protect the air conditioner.
4-7. EXPLANATION TO THE USER
• Using the OPERATING INSTRUCTIONS, explain to the user how to
use the air conditioner. (how to use the remote controller, how to re-
move the air filters, how to remove or put the remote controller in the
remote controller holder, how to clean, precautions for operation, etc.).
• Recommend the user to read the OPERATING INSTRUCTIONS care-
fully.
8