Dual channel bearing vibration monitor
Vorschau ausblenden Andere Handbücher für CSI 6500 Machinery Health Monitor:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Product Information / Produktinformation A6120
Bearing Vibration Monitor
Current outputs−characteristic values
Characteristic value formation and evaluation depends on the functions specified in the
configuration.
Current output 1 − I1+ /I1−
Current output 2 − I2+ / I2−
Nominal range
−Life zero operation
Precision / resolution
Per. load resistance
Signal outputs EO 1 / EO 2
d14 / d16
Voltage outputs 0...10V proportional to the bearing vibration, measuring range and signal
evaluation according to the characteristical variables channel 1 (EO 1) and channel 2 (EO 2).
Open circuit and short circuit proof, non reactive.
Nominal range
Resolution
Per. load resistance
Internal resistance
Signal inputs EI1 / EI2
Inputs for single−channel measurement values 0 ... +10 V for connection with EO outputs
(not relevant for MMS 6120 module).
Voltage input EI1 / EI2
Nominal voltage range
Resolution
Internal resistance
Signal input KEY
The key pulse is required for internal RPM determination for checking the measurements in
the measured value analysis.
Signal input KEY (N)
Signal level
Input resistance
z18 / b18 (0 V / common)
z20 / b20 (0 V / common)
0 ... 20 mA or 4 ... 20 mA, depending on the
configuration
in 4 ... 20 mA operation you can specify via the
configuration that the output is set to 0 mA if a fault is
detected.
±1 % of f.s.d. / 16 Bit
500 Ω
0 ... +10 V DC
8−bit
> 10 kΩ
Approximately 50 Ω
b14 / b16
0 ... +10 V DC
10−bit
> 100 kΩ
d22
24 V logic,: LOW = 0 ... 3 V; HIGH = 13 ... 48 V
> 10 kΩ
Page 15