Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting; Technical Specifications - GreenWorks 4104107 Bedienungsanleitung

Ölfreier druckluftkompressor
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 6
EN
DE ES IT FR PT NL RU FI SV NO DA PL CS SK SL HR HU RO BG EL AR TR HE LT LV ET
TROUBLE SHOOTING
Prior to all servicing:
Switch machine off. Disconnect the mains plug. Wait
until the device has stopped. Ensure that there is no
more pressure on the device and all used compressed
air tools and accessories.
Leave the device and all used compressed air tools
and accessories to cool down.
Any works other than the ones described in this
chapter, must be carried out only by a qualified
electrician or the service branch in your country.
After all servicing:
Put back into operation and check all safety installations.
Ensure that there are no tools or similar at or in the device.
Compressor does not run:
• No mains voltage.
– Check cables, plug, outlet and mains fuse.
• Mains voltage too low.
– Use only extension cables with sufficient lead cross-
section. For cold device: Avoid extension cable. For cold
device: Depressurise the pressure vessel.
• Compressor was switched off by pulling the mains plug
while it was running.
– First, switch off the compressor using the ON/ OFF
switch (9), then switch on again.
• Motor overheated, e.g. due to insufficient cooling
(cooling ribs covered).
– Switch off the compressor using the ON/OFF switch (9) .
– Remedy the cause for overheating. Leave to cool
for about ten minutes.
– Switch on the compressor again using the ON/ OFF
switch (9) .
Compressor runs without building up sufficient
pressure.
• Condensate outlet leaking.
– Ensure that the condensate outlet (3) is closed.
– Check the seal of the drainage plug, if required,
replace.
• Check valve leaking.
– Have check valve serviced in authorised service
centre.
Compressed air tool does not get enough pressure.
• Pressure controller not open enough.
– Open pressure controller (7) further.
English (Original Instructions)
DANGER
• Hose connection between compressor and compressed
air tool leaking.
– Check hose connection; if required replace
damaged parts.

TECHNICAL SPECIFICATIONS

Input
Output
Max. working pressure
Pressure vessel volume
No. of air outlets
No. of cylinders
Motor speed
Motor capacity
Supply voltage (50 Hz)
Rated current
Degree of protection
Max. overall cable length when
using extension cables:
– at 3 x 1.0 mm2 lead cross section
– at 3 x 1.5 mm2 lead cross section
– at 3 x 2.5 mm2 lead cross section
Weight
Sound pressure level
5
220 l/min
120 l/min
8 bar
24 L
1
1
2850 min-1
1.5 kW
230 V
6.0 A
IP 20
10 m
25 m
25 m
24 kg
97 dB (A)

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis