Measuring Resistance; Diodetest; Continuity Test - Herth+Buss Claw 100 Bedienhinweis

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating Instruction
re proceeding. lt is necessary for accurate
measurements.
3. The meter's measuring capacity is 100A.
Measuring a current higher than 100A
will cause a larger measurement error.
4. Don't use the meter to measure a circuit's
current if the circuit's voltage exceeds
600V.

Measuring Resistance

1. Connect the black test Iead to the „COM"
terminal and the red test Iead to the„
" terminal.
2. Set the function switch to the Ω position.
3. Connect the test Ieads across the object
to be tested.
4. Read the reading on the display.
Note:
1. lf the resistance is more than 1MΩ, it may
take several seconds for the reading to
stabilize. This is normal for high resis-
tance measurements.
2. lf the input terminals are in open circuit
state, the overrange indicator „OL " will be
shown on the display.
3. Before measurement, disconnect all po-
wer to the circuit to be tested and dischar-
ge all capacitors thoroughly.

DiodeTest

1. Connect the black test Iead to the „COM„
terminal and the red test Iead to the „
" terminal. ( The red test Iead is po-
sitive „ + „. )
2. Set the function switch to
Then press the „RANGE/
www.herthundbuss.com
the symbol
3. Connect the red test Iead to the anode of
the diode to be tested and the black test
Iead to the cathode of the diode.
4. Read the approximate forward voltage
drop of the diode on the display.

Continuity Test

1. Connect the black test Iead to the „COM"
terminal and the red test Iead to the„
2. Set the function switch to
Then press the „RANGE/
the symbol
3. Connect the test Ieads across the circuit
to be tested.
4. If the resistance is less than about 50Ω,
the built-in buzzer will sound.
Note:
Before test, disconnect all power to the cir-
cuit to be tested and discharge all capacitors
thoroughly.
Automatic Power-off
lf you have not used the meter or rotated
the function switch for about 15 minutes, the
meter will turn off automatically and go into
Sleep mode.
To arouse the meter from Sleep, rotate the
function switch or press a button.
If you press the „RANGE/
arouse the meter from Sleep when the func-
tion switch is in the „ "or „
automatic power-off feature will be disabled.
position.
"button until
appears on the display.
"terminal.
appears on the display.
" position, the
95980776
position.
„ button until
„ button to
26