Herunterladen Inhalt Inhalt Diese Seite drucken

Measuring Ac Voltage; Measuring Dc Current; Measuring Ac Current - Herth+Buss Claw 100 Bedienhinweis

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operating Instruction
to the meter, do not apply a voltage higher
than 600V between terminals.

Measuring AC Voltage

1. Connect the black test Iead to the „COM"
terminal and the red test Iead to the „
" terminal.
2. Set the function switch to Ṽ position.
3. Connect the test Ieads across the source
or circuit to bo tested.
4. Read the reading on the display.
Note:
To avoid electrlc shock to you or damages to
the meter, do not apply a valtage higher than
600V between terminals.

Measuring DC Current

1. Set the function switch to the
2. lf the display does not read zero, press
the „
" button for zeroing.
3. Press tha trigger and clamp the jaws
around the conductor to be tested. Make
sure that the jaws are perfectly closed.
Note:
a. Each time only one conductor should
be clamped.
b. The conductor should be in the center
of the jaws in order to get accurate rea-
ding.
c. Don't touch any conductor with hand or
skin.
4. Read the reading on the display.
Note:
1. Remove all the test Ieads from the meter
before using the meter for current mea-
surements.
25
2. After you set ‚the function switch to the
position, wait about 5 to 10 minutes befo-
re proceeding. lt is necessary for accurate
measurements.
3. The meter's measuring capacity is 100A.
Measuring a current higher than 100A
will cause a larger measurement error.
4. The reading on the displayalso indicates
the current's direction: A positive reading
(negative sign „-" doesn't appear) indica-
tes that the current direction is from the
meter's front to its back. ( Note: Current
direction is the opposite of electron flow
direction.)
5. Don't use the meter to measure a circuit's
current if the circuit's voltage exceeds
600V.
position.

Measuring AC Current

1. Set the function switch to the à position.
2. Press the trigger and clamp the jaws
around the conductor to be tested. Make
sure that tha jaws are perfectly closed.
Note:
a. Each time only one conductor should be
clamped.
b. The conductor should be in the center of
the jaws in order to get accurate reading.
c. Don't touch any conductor with hand or
skin.
3. Read the reading on the display.
Note:
1. Remove all the test Ieads from the meter
before using the meter for current mea-
surements.
2. After you set the function switch to the Ã
position, wait about 5 to 10 minutes befo-
95980776

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Verwandte Produkte für Herth+Buss Claw 100