17. Do not use the test Ieads with other
equipments.
18. Remaining endangerment: When an in-
put terminal is connected to dangerous
live potential, this potential can occur at
all other terminals!
19. CAT III - Measurement Category III is for
measurements performed in the building
installation. Examples are measurements
on distribution boards, circuit breakers,
wiring, including cables, bus-bars, junc-
tion boxes, switches, socket-outlets in the
fixed installation, and equipment for in-
dustrial use and some other equipment,
for example, stationary motors with per-
manent connection to fixed installation.
Do not use the meter for measurements
within Measurement Categories IV.

Caution

To avoid possible damage to the meter or to
the equipment under test, follow these gui-
delines:
1. Disconnect circuit power and discharge
all capacitors before testing resistance,
diode and continuity.
2. Use the proper function and range for
your measurements.
3. Before rotating the function switch to
change functions, remove test Ieads from
the circuit under test and remove the
jaws from the clamped conductor.
www.herthundbuss.com

Electrical Symbols

Alternating Current
Direct Current
Both direct and a!temating current
Caution, risk of danger, refer to the
operating manual before use.
Caution, risk of electric shock,
Earth (ground) Terminal
Conforms to European Union directives
The equipment is protected throughout
by double insulation or reinforced
insulation.
Application araund and removal from
hazardous live oonductors is permitted.

Introduction

This meter is a 3 3/4-digit autorange digital
clamp meter for measuring DC and AC volta-
ge, DC and AC current, resistance, diode and
continuity. lt features relative measurement,
Data Hold mode, autorange and manual ran-
ge mode, low battery indication, overrange
indication, automatic power-off, and etc. lt is
easy to operate and is an ideal measurement
tool.
General Specification
Display: 3 3/4-digit LCD, with a max. rea-
ding of 3999
Negative Polarity lndication: negative sign
„ _ „ shown on the display automatically
Overrange lndication: „OL " shown on the
display
Jaw Opening Cepability: 10 mm
Max. Measurable Condudor: ø 10mm
Battery: 1.5V battery, AAA or equivalent,
two pieces