Timer Mode
In timer mode, the haze machine will output fog in pre-configured time intervals (see Timer Mode
Parameters below).
1.
Press <TIMER> until a timer is displayed.
2.
The haze machine starts outputting fog when the counter reaches zero (0).
3.
Set the timer duration in the DURATION SET menu option; set the output volume in the TIMER OUT
menu option.
4.
The cycle repeats itself until you press <TIMER> again or until the haze machine runs out of fluid.
Manual Mode
In manual mode, the haze machine will output fog for as long as the button remains pressed. The output
volume will be at 100 % output volume.
1.
Keep <MANUAL> pressed to output fog.
2.
Release <MANUAL> to stop the fog output.
Time Mode Parameters
These parameters determine the interval and output volume in timer mode.
1.
Press <FUNCTION> repeatedly until INTERVAL SET is displayed.
2.
Select the interval time (1-200 sec.) with <UP> or <DOWN>.
3.
Press <FUNCTION> repeatedly until DURATION SET is displayed.
4.
Select the duration time (1-200 sec.) with <UP> or <DOWN>.
5.
Press <FUNCTION> repeatedly until TIMER OUT is displayed.
6.
Select the desired output volume (1-100 % or non-stop) with <UP> or <DOWN>.
When the haze machine is connected to a DMX controller, this controller
will take priority to the on-board control panel of the haze machine.
Remove the DMX cable before using the on-board control panel.
8.

Troubleshooting

problem
The fuse keeps blowing.
The haze machine does not
power.
The haze machine does not
respond to DMX.
V. 01 – 21/12/2015
HQHZ10001/HQHZ10002
possible cause
Excessive load on the circuit.
Short-circuit along the power
line.
No power on the mains.
Loose or damaged power cord.
Blown fuse.
Internal problem.
Wrong starting address.
Wrong manipulation on the
controller.
Incorrect; loose or damaged
DMX cord.
Internal problem.
Interference with radio signals.
DMX cable too long.
Too many products connected.
Terminator not connected.
9
possible solution
Make sure that the total load
does not exceed 80 % of the
fuse's nominal current.
Check the power line.
Check the mains.
Check the power cord.
Replace the blown fuse.
Send the haze machine for
repair.
Set the correct DMX address on
the haze machine.
Manipulate the correct controls
on the controller.
Check the DMX cord.
Send the haze machine for
repair.
Keep the DMX cable away from
radio equipment.
Install an optically-coupled DMX
amplifier before the machine.
Install an optically-coupled DMX
amplifier.
Connect the terminator.
©Velleman nv