Preparing your Haze Machine
1.
Remove the fluid tank from its compartment. Also, remove the cap.
2.
Verify that the plastic hoses attached to the cap are in place and in good condition.
3.
Pour fog fluid into the tank and close the tank.
4.
Replace the tank into its compartment. Make sure the plastic hose entering the haze machine from
the fluid tank is not bent or kinked.
5.
Connect the haze machine to the mains, switch it on and let it warm up. The haze machine is ready-
to-use after approximately 7 to 8 minutes.
In any operation mode, the display must read READY TO FOG to output
Start-Up
1.
Make sure the haze machine is switched off before connecting it to the mains.
2.
Switch on the haze machine.
3.
Press <VOLUME>.
4.
Adjust the fog output volume with <UP> or <DOWN>.
DMX Configuration
To set the haze machine in DMX mode:
1.
Connect the haze machine to the mains, switch it on and let it warm up.
2.
Connect a DMX cable to the DMX input of the haze machine and the DMX output of a controller (not
included).
3.
To activate the DMX function, press <FUNCTION> repeatedly until DMX512 ADD is displayed.
Select the start address from 1 to 512 with <UP> or <DOWN>.
Make sure that the starting address of the interconnected haze machines
A DMX terminator is recommended for installations where the DMX cable has to run a long distance or is
in an electrically noisy environment (e.g. discos). The terminator prevents corruption of the digital
control signal by electrical noise. The DMX terminator is simply an XLR plug with a 120 Ω resistor
between pins 2 and 3, which is then plugged into the XLR output socket of the last device in the chain.
Setting the Output Volume
1.
Press <FUNCTION> repeatedly until VOLUME OUT is displayed.
2.
Select the desired output volume (1-100 % or non-stop) with <UP> or <DOWN>.
3.
Press <VOLUME> to confirm.
4.
Press <VOLUME> again to trigger the fog at the set output.
The haze machine will memorize the set output after switch-off. To reset
Activating the Fluid Sensor
The integrated fluid sensor measures the fluid level in the tank. To activate the fluid sensor:
1.
Press <FUNCTION> repeatedly until FLUID SENSOR is displayed.
2.
Select ON with <UP> or <DOWN>.
3.
Select OFF with <UP> or <DOWN> to deactivate the fluid sensor.
Setting the Fan
1.
Press <FUNCTION> repeatedly until FAN SET is displayed.
2.
Select ON with <UP> or <DOWN>.
3.
Select OFF with <UP> or <DOWN> to deactivate the fan.
V. 01 – 21/12/2015
HQHZ10001/HQHZ10002
fog.
do not overlap.
the fog output, repeat the steps above.