Herunterladen Inhalt Inhalt Diese Seite drucken
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 42
4.4
Connection
Have a qualified electrician carry out the electric connection.
Connect the device to the mains with the power plug. All devices must be powered
directly off a grounded switched circuit. Do not connect to a dimmer pack.
The installation has to be approved by an expert before the device is taken into service.
DMX-512 Connection
When applicable, connect an XLR cable to the female XLR output of a controller (not
incl.) and the other side to the male XLR input of the device. Multiple devices can be
linked through serial linking. The linking cable shall be a dual core, screened cable with
XLR input and output connectors.
A DMX terminator is recommended for installations where the DMX cable has to run a
long distance or is in an electrically noisy environment (e.g. discos). The terminator
prevents corruption of the digital control signal by electrical noise. The DMX terminator
is simply an XLR plug with a 120 Ω resistor between pins 2 and 3, which is then plugged
into the XLR output socket of the last device in the chain.
5.
Overview
Refer to the illustrations on page 2 of this manual.
1
2
3
6.
Operation
6.1

Control Panel

Access the control panel functions using the four buttons below the display.
button
MENU
UP
DOWN
ENTER
V. 03 – 18/07/2018
safety switch
display + menu buttons
safety eye
to access the menu, quit the current function without saving the setting,
or quit the menu
to scroll upward in a list of functions or options, or increase a value
to scroll downward in a list of functions or options, or decrease a value
to confirm and save a selected option or value
HQLE10036
4
5
function
9
DMX input/output
power input/output
©Velleman nv

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis