Follow the steps below to mount the antenna on a ceiling using brackets:
1. Drill holes for the brackets (6 mm diameter) in the wall and insert the plugs in the
holes.
2. Remove the protective caps from the QMA connectors of the antenna.
3. Connect the QMA/N-Connect cables to the antenna.
4. Secure the brackets with screws, washers and nuts to the antenna as illustrated.
The maximum tightening torque is 12 Nm.
5. Bend the QMA/N-Connect cables to form a 90° angle (minimum bending radius:
28 mm).
6. Secure the brackets mounted on the antenna to the wall with screws.
ANT795-6MT