Characteristic
ij
Others
kl
Others
* Optional, for intrinsically safe version:
 blue cable coating
or
 marked with blue heat shrink tubing
1.2 Electrical specification (sensors not
operated in intrinsically safe mode)
Sensor 671 *** M** **-**, 671 *** N** **-** (with potential
terminal)
Voltage rating
( V AC/DC)
Rated current (mA), static
Power rating (W/VA)
Temperature class /
max. ambient temperature 2G
max. ambient temperature 2D
Protection class
* -25 °C ... 75 °C T5 / II 2D / II 1D
(ANSI/UL 508/CSA C22.2#14-10)
 Ensure that the sum of all component currents does not
exceed the given current rating of the sensor.
 Ensure that the maximum rated current per switching contact
does not exceed 75 mA.
35/135
Type
Meaning
Customer-specific
Extra cable length (standard: 1m)
671 *** M** **-**
671 *** N** **-**
24
60
5
T5 / 85 °C*
T6 / 70 °C
85° C
IP 68 10 bar (IEC 529)
150
5
T5 / 70 °C
T6 / 50 °C
70° C
Date: 20.04.2016