INSTRUCTIONS FOR USE

Fluid Dispensing

1 .
Unscrew the lid w/ pump from the reservoir, and
fill to desired level with clean fluid .
Note:There are two scales of volume on the res-
ervoir . One scale indicates the volume when the
lid w/ pump is removed and one when the lid w/
pump is installed . Be sure to note the appropriate
scale .
CAUTION: If fluid is added above the MAX FILL line,
the reservoir will overflow when the lid w/ pump is
installed .
2 .
Reinstall the lid w/ pump onto the reservoir .
3 .
Connect the fluid dispensing hose or other acces-
sory to the quick-connect coupler extending from
the reservoir . Ensure the coupler sleeve snaps
forward to lock the
connection .
Note: Depending on the application, the shutoff
valve installed in the fluid dispensing hose may be
left open or closed . If left open, fluid will begin to
flow as soon as the pump is operated . If closed,
pressure will build in the reservoir as indicated on
the gauge .
4 .
While observing the pressure gauge, operate the
pump to build pressure in the reservoir to the
desired level, or until the desired amount of fluid
has been dispensed .
Note: A built-in pressure relief valve is designed to
open and maintain maximum pressure between
17 and 23 psi (1 . 2 and 1 . 6 bar) .
Continual operation of the pump is not required
to maintain fluid flow . Fluid will continue to flow
as long as there is pressure in the reservoir and the
shutoff valve is open .
WARNING: Do not exceed 25 psi (1 . 7 bar) pressure
in the reservoir . The relief valve should prevent
this, but if it fails and the pressure exceeds 25 psi,
immediately discontinue use and send the unit to
an authorized service center for repair or replace-
ment .
5 .
Once the proper amount of fluid has been dis-
pensed, close the shutoff valve and bleed off the
pressure by tilting the pressure relief knob located
on the lid .
Form 801193
6 .
Depending on the type of fluid and future intend-
ed use, you may store the remaining fluid from the
reservoir . Otherwise empty the reservoir, clean it
with denatured alcohol or a common household
cleaner, and store it properly .