5.1 Adjusting the receiver
When the receiver is not locked, press the button
SET (6) to activate the setting modes one after
another:
group (keep button pressed for a while)  channel
 scan function  identification number  lock
function
To make settings in a setting mode, see the corre-
sponding chapter (5 .1 .1 to 5 .1 .4) .
To exit a setting mode without changing a setting,
press the button SET repeatedly until the display
briefly shows
then return to the normal mode .
5.1.1 Transmission frequency (group /channel)
To set the transmission frequency, select the chan-
nel group and the channel . Six channel groups with
preset channels in different numbers are available
table on page 24 .
Note: To prevent interference, carefully match the trans-
mission frequencies of all transmission paths at the place
of application to one another . In case of parallel operation
of several channels, it is recommended to use channels
from the same group .
1) Keep the button SET (6) pressed until the letter
"G" starts flashing on the display; the group
setting mode is activated .
2) Select the group (
or the button
3) Press the button SET to confirm . The letters
"CH" start flashing on the display; the channel
setting mode is activated .
4) Select the channel with the button
the scan function has been activated (
ter 5 .1 .2), each time a channel is selected, the
unit will check if the corresponding transmission
frequency is presently being used for transmis-
sion (brief insertion
If it is, this channel already used will be skipped .
5) Press the button SET to confirm . The display
briefly shows
return to the normal mode .
12
(= cancel) . The receiver will
. . .
) with the button
(7) .
or . When
= "scan channel") .
(= store) . The receiver will
5.1.2 Scan function
The scan function makes it easier to select a free
transmission frequency: When the function has
been activated, the frequencies already being used
for transmission will be skipped when you set the
transmission frequency (
1) Keep the button SET (6) pressed until the letter
"G" starts flashing on the display; the group
setting mode is activated .
2) Press the button SET repeatedly until the display
shows the current setting for the scan function:
3) Press the button
or the button
4) Press the button SET to confirm . The display
briefly shows
the normal mode .
5.1.3 Identification number
To set the transmitter to the transmission fre-
quency of the receiver via the REMOSET function
(
chapter 5 .2), both must have the same iden-
tification number .
1) Keep the button SET (6) pressed until the letter
"G" starts flashing on the display; the group
setting mode is activated .
(5)
2) Press the button SET repeatedly until the display
shows
( ...
3) Select the desired number with the button
or the button
chap-
4) Press the button SET to confirm . The display
briefly shows
the normal mode .
5) Then set the identification number on the trans-
mitter
5.1.4 Lock function
When the lock function has been activated, the
REMOSET function will not be available (
ter 5 .2) and it will not be possible to switch off the
receiver . From the setting modes, you will only be
able to activate the mode for the lock function in
order to deactivate the lock .
chapter 5 .1 .1) .
scan function activated
scan function deactivated
(5) to select the setting
(7) to select the setting
. The receiver will return to
and the current identification number
) .
(7) .
. The receiver will return to
instruction manual of the transmitter .
.