Herunterladen Inhalt Inhalt Diese Seite drucken

Ugolini MT GL Gebrauchsanweisung Seite 16

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 24
MT GL
dust from the condenser filter. A blocked filter will reduce
ATTENTION
Before any disassembly and/or cleaning procedure make
sure that the dispenser is disconnected from its power
source by unplugging it.
performance and could cause compressor failure.
Remove the only left panel (from faucet side) unscrewing the
two plastic coated screws (see figure 16).
figure 16
ATTENTION
Condenser fins are very sharp. Use extreme caution
when cleaning.
3 Replacement of lighted top cover bulb: remove the fixing
screw placed in the upper part of the top cover, remove the
lower part and replace the bulb (using a 24-28V 21W max
bulb). Reassemble the top cover and replace the fixing
screw.(see figure 17)
figure 17
6. 1 MAINTENANCE (TO BE CARRIED OUT BY
QUALIFIED SERVICE PERSONNEL ONLY)
1 Monthly on MT 1 P model: remove the dust from the
condenser. To do this unplug the unit.
2 Annually: remove the panels and clean the inside of the
machine including the base, side panels, condenser, etc.
3 Annually: Check if the auger bushings are worn out or
ovalized. If they are, replace them with new ones.
4 Never remove the insulating jacket from around the suction
tubing of the evaporator (the copper tubing located on the right
side of gear motor). In case the insulating jacket is missing
replace the entire parts with original spare parts from the
supplier.
5 In order to prevent any damages to the dispenser, all
plastics parts must be lubricated only with grease supplied by
the manufacturer or with another lubricating product suitable for
polycarbonate.
IMPORTANT
The electric diagram of the dispenser is located in the
inner part of the dispensing side panel.
16

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis