WARNING!
Motor drive handling
The circuit breaker in revision position:
Removal of the motor drive from the circuit breaker:
1. Disconnect the OD-BL-KA01 connector, or wiring from the motor drive
2. Select Manual mode on the motor drive.
3. Pull on the lever of the drive spring mechanism.
4. Remove the motor drive from the circuit breaker.
Installation of the motor drive on the circuit breaker:
1. Pull on the circuit breaker lever (unless this is pulled on from the previous cycle)
2. Select the manual mode on the motor drive, and pull on the lever (drive spring
mechanism) (unless this is pulled on from the previous cycle)
3. Put the motor drive on the circuit breaker.
4. Switch on the circuit breaker by means of the green button on the front side of
the motor drive
5. Trip the circuit breaker by means of TEST button.
6. Slide the circuit breaker from the revision to working position
7. Change the motor drive mode from auto to manual (if this is required and unless
it has already been made)
8. Connect the OD-BL-KA01 connector, or wiring of the motor drive.
When the green light "Active" is ON, the whole assembly is ready for use.
When the red light "Reset" is ON, the drive has to be restarted by disconnecting
and re-connecting the power supply.
The circuit breaker in working position:
Removal of the motor drive from the circuit breaker:
1. Disconnect the OD-BL-KA01 connector, or wiring from the motor drive
2. Select MANUAL mode on the motor drive.
3. Pull on the lever of the drive spring mechanism.
4. Remove the motor drive from the circuit breaker.
Installation of the motor drive on the circuit breaker:
1. Pull on the circuit breaker lever (unless this is pulled on from the previous cycle)
2. Select the manual mode on the motor drive, and pull on the lever (drive spring
mechanism) (unless this is pulled on from the previous cycle).
3. Put the motor drive on the circuit breaker.
4. Change the motor drive mode from MANUAL to AUTO (if this is required and
unless it has already been made)
5. Connect the OD-BL-KA01 connector, or wiring of the motor drive.
When the green light "Active" is ON, the whole assembly is ready for use.
When the red light "Reset" is ON, the drive has to be restarted by disconnecting
and re-connecting the power supply.