Introduction
1. Introduction
The Domonial CMI is a wireless control panel with a built-in siren, digital communicator and audio
verification system. The radio link between the various components of the system allows easy installation
without the need for much cabling. This version can be used with the "HF" (except CLB800HF) and the "M"
device ranges (e.g. DO800M).
Programming of the control panel and digital communicator can be done using the following tools:
► The PDA or PC programming tools. Refer to the DOMOPDA Programming Manual or
the DomoPC online programming guide for full details.
► A TCU keypad.
This guide describes how to program the panel using the TCU keypad. For more detailed explanations,
please refer to the Installation Manual.
1.1 The Contents of the Box
► CMI800++ panel, plus this Quick Guide for Installers and the TCU Programming Guide: Code
Reference.
► 1 Stocko, four-pin connector inside the panel for the telephone connection.
► Breakout tabs for covering unused wire passages.
► A velcro strap for securing the battery.
The panel has a built-in mains supply and uses a 4V- 3.5A/h back-up battery (sold separately).
Batteries delivered by Honeywell: ELECKSON BPEL040035, SONNENSCHEIN A504/3.5S.
Panel Label
Commercial reference
Product file reference
Serial number
Date of manufacture
The software version number is marked on a label on the box containing the panel (e.g. SW:K05) e and on a
small label on the PCB.

1.2 The LED Indicators

The CMI800 panel comes in two designs, depending on the version. Both designs have LED indicator lights
showing the status of the system.
LED layout for the classic version (version I and later)
State/LED
Mains
Supply
Colour
Green
CMI8UK-STD-5
97AGCOB
75000C6C8
060720
Arm/Disarm Perimeter Fault Intruder Alarm
Green
Yellow
Note: The format of the date is yymmdd.
Technical
Memory
Alarm Memory
Red