Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Limits; Declaration Of Conformity - Technibel GR9FI42R5I-series Installationsanleitungen

Vorschau ausblenden Andere Handbücher für GR9FI42R5I-series:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

í Cooling Maximum conditions
Outdoor temperature :
Room temperature :
í Cooling Minimum conditions
Outdoor temperature :
Room temperature :
Outdoor - Indoor unit combination table
system type
outdoor unit
mono split
GR9FI42R5I--
mono split
GR9FI50R5I--
dual split
GR9FI42R5I--
dual split
GR9FI50R5I--
Tools required for installation (not supplied)
1. Standard screwdriver
2. Phillips head screwdriver
3. Knife or wire stripper
4. Tape measure
5. Level
6. Sabre saw or key hole saw
7. Hacksaw
8. Core bits ø 5

DECLARATION OF CONFORMITY

This product is marked
– Low voltage no. 2006/95/EC. (Standard: EN60335-2-40:2003 (incl. Corr.:2006) + A11:2004 + A12:2005 + A13:2012
+ A1:2006 + A2:2009 con EN 60335-1:2002 + A11:2004 + A1:2004 + A12:2006 + A2:2006 + A13:2008 + A14:2010 +
A15:2011).
– Electromagnetic compatibility no. 2004/108/EC, 92/31 EEC and 93/68 EEC. (Standard: EN55014-1 (2006) + A1(2009)
+ A2(2011), EN 55014-2 (1997) + A1(2001) + A2 (2008), EN 61000-3-2 (2006) + A1(2009) + A2(2009),
EN 61000-3-3 (2008)
– RoHS2 no.2011/65/EU.
– Regulation (EU) no. 206/2012, of 6 march 2012, concerning the specifications for ecodesign requirements of air
conditioners and fans.
– Regulation (EU) no. 626/2011, of 4 may 2011, concerning the labeling indicating the energy consumption of air
conditioners.
This declaration will become void in case of misuse and/or non observance though partial of manufacturer's installation
and/or operating instructions.

OPERATING LIMITS

43°C D.B.
32°C D.B. / 23°C W.B.
–15°C D.B.
10°C D.B. / 6°C W.B.
a
Indoor unit - circuit
Indoor unit - circuit
A
B
B
C
A
A
A
19. Hammer
10. Drill
11. Tube cutter
12. Tube flaring tool
13. Torque wrench
14. Adjustable wrench
15. Reamer (for reburring)
16. Hex. key
as it satisfies Directives:
í Heating Maximum conditions
Outdoor temperature :
Room temperature :
í Heating Minimum conditions
Outdoor temperature :
Room temperature :
b
A - B - C = indoor unit size
(see catalogue)
Power Supply: 220 - 240 V ~ 50 Hz
A
A
B
REGULATION (EU) No. 517/2014 - F-GAS
The unit contains R410A, a fluorinated greenhouse gas with
a global warming potential (GWP) of 2087.50. Do not
release R410A into the atmosphere.
R410A: 1.30 kg / 2.71 Tonn.CO2
5
24°C D.B. / 18°C W.B.
27°C D.B.
–15°C D.B.
5°C D.B.
(go on page 6)
EG

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Gr9fi50r5i-series

Inhaltsverzeichnis