Herunterladen Inhalt Inhalt Diese Seite drucken

Operating Limits - Technibel GR9FI80R5I Serie Installationsanleitungen

Split-klimagerät
Vorschau ausblenden Andere Handbücher für GR9FI80R5I Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 26
MODEL
GR9FI80R5
MONO SPLIT
DUAL SPLIT
TRIAL SPLIT
GR9FI80R7
QUADRI SPLIT
GR9FI110R5
MONO SPLIT
DUAL SPLIT
TRIAL SPLIT
GR9FI110R7
QUADRI SPLIT
Supply power wire A:
Multipolar electric wire. Size and length of the suggested electric wire are showed on table "electrical data". The wire
must be Mod. H07RN-F (according to CEI 20-19 CENELEC HD 22). Make sure the length of the conductors between
the fixing point and the terminals allows the straining of the conductors L, N before that of the grounding.
Connecting wire B (SHIELDED):
Bipolar electric shielded wire; size and length of the suggested electric wire are showed on table "electrical data".
The wires have not to be lighter than Mod. H05VVC4V5-K (according to CEI 20-20 CENELEC HD21).
Connecting wire C (with ground conductor):
Multipolar electric wire; size and length of the suggested electric wire are showed on table "electrical data". The
wires have not to be lighter than Mod. H07RN-F (according to CEI 20-19 CENELEC HD22).
ADDITIONAL MATERIAL REQUIRED FOR INSTALLATION (NOT SUPPLIED)
Deoxidized annealed copper tube for refrigerant tubing connecting the units of the system; it has to be insulated with
foamed polyethylene (min. thickness 8mm).
INDOOR UNIT SIZE
OUTER DIAMETER
A
B - C - D
D (CA)
PVC pipe for condensate drain pipe (ø int.18mm) in length suitable to let the condensate flow into the outside drainage.
Anti-freeze oil for flare connections (about 30g.).
Electric wire: use insulated copper wires of size and length as shown at paragraph "SYSTEM WIRING DIAGRAMS".
í Cooling Maximum conditions
Outdoor temperature :
Room temperature :
í Cooling Minimum conditions
Outdoor temperature :
Room temperature :
LENGTH, SIZE WIRES AND DELAYED FUSE
L ("A") m
2
mm
2,5
20
20
20
20
2
mm
4
20
20
20
20
NARROW TUBE
MIN. THICKNESS
6,35 mm
6,35 mm
9,52 mm

OPERATING LIMITS

43°C D.B.
32°C D.B. / 23°C W.B.
–15°C D.B.
10°C D.B. / 6°C W.B.
L ("B") m
0,75
50
30
30
30
0,75
50
30
30
30
OUTER DIAMETER
0,8 mm
9,52 mm
0,8 mm
12,7 mm
0,8 mm
15,88 mm
í Heating Maximum conditions
Outdoor temperature :
Room temperature :
í Heating Minimum conditions
Outdoor temperature :
Room temperature :
7
L ("C") m
1,5
50
20 A
30
30
30
1,5
50
25 A
30
30
30
LARGE TUBE
MIN. THICKNESS
0,8 mm
0,8 mm
1 mm
24°C D.B. / 18°C W.B.
27°C D.B.
–15°C D.B.
5°C D.B.
EG

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis