TECHNICAL DATA:
DIMENSIONS :
H x W x D (cm)
WEIGHT:
RATED OUTPUT:
CLASS TO EN 13 240:
FLUE GAS OUTLET – top:
REQUIRED NEGATIVE PRESSURE IN THE CHIMNEY :
FLUE GAS FLOW RATE:
MEAN FLUE GAS TEMPERATURE:

INSTALLATION INSTRUCTIONS

The stoves are delivered in carton boxes, fixed on transport pallets. Preferably, the stoves should be
unpacked at the installation site. The stoves are designed for top flue connection.
Ambient conditions
If the stove is to be installed in a room with combustible or heat sensitive flooring, a solid non-
combustible floor protector is required under the stove. The floor protector should be dimensioned to
extend at least 20 cm to the back and lateral sides and 40 cm to the front of the stove.
Minimum clearance between the stove (sides and rear) and materials sensitive to heat is 45 cm.
Minimum clearance between the stove and heat sensitive materials within the area directly exposed
to heat in front of the stove shall be 80 cm.
The stove should be positioned on a level surface, in a room with sufficient fresh air supply to support
the combustion. If an aspirator (range or fireplace hood) or any other air consuming device is installed
in the same room, make sure to provide for regular inflow of fresh air through a separate opening
protected with a clog-proof grid.
Chimney connection
Common (standard) stovepipes and elbows of nominal diameter Ø120 mm (inner stovepipe diameter
is Ø118 mm) are recommended for the connection to the chimney.
Make sure that the stovepipe and elbow are tightly fastened together and that the connections of the
stovepipe with the flue outlet and with the chimney outlet are firm and tight. The stovepipe shall not
extend beyond the chimney liner, i.e. it must not protrude into the cross section of the chimney. Make
sure to provide adequate access for the cleaning of the stove, stovepipes and chimney.
Good heating performance will be achieved if the stove is connected to a properly designed and
maintained chimney, ensuring good draught i.e. negative pressure of 1-2 mm w.c. Only one stove
(one unit) shall be connected to the chimney. The stove shall be installed in full compliance with
applicable European, national as well as local regulations.
INSTRUCTIONS FOR USE
Fuel
The stoves have been designed to burn wood, wood briquettes and brown coal briquettes.
Use only well-seasoned dry wood to reduce the likelihood of greasy soot (creosote) build-up, which
may cause clogging of the chimney.
Do not burn household waste, especially not any plastic material. Many waste materials contain
substances that are harmful to the stove, the chimney and the environment.
Also, never burn chipboard waste, because chipboard contains glues which may cause overheating
of the stove.
DORA 8 - NERA 8
85 x 38 x 42 cm
64 - 63 kg
6 kW
1a
Ø118/120 mm
12 Pa
7,4 gr/sek
323 °C
28
DORA 10 - NERA 10
99 x 38 x 42 cm
65 - 64 kg
7 kW
1a
Ø118/120 mm
12 Pa
8,3 gr/sek
284 °C