Removing the insulation
The insulation on UKV 500 can be removed to facilitate
work in confined spaces. (The diameter without insula-
tion is UKV 500 Ø662 mm).
Remove all screws along the joining plate.
Lift off the top cover.
Remove the insulated jacket.
Pull the insulated parts straight out.
The figure shows removal of insulation on UKV 500
Carry out assembly in reverse order.
Finally, fit all the enclosed cover discs on each connection
by pressing them over the connections.
NOTE
Fit the cover discs and the insulation plugs be-
fore installing the pipe.