The smart charging technology that has a replaceable head system is fitted
with a Delta-U and time controlled switch-off mechanism as well as with a
temperature checker for the batteries.
The device is compliant with all relevant standards of electromagnetic
compatibility, the safety of laser products and the restriction of the use of certain
hazardous substances (RoHS).
Versions
The DOCTER
®
aspherilux midi LED is available in green and anthracite finish
Commissioning & Operation
The integrated batteries are pre-charged only.
Commissioning
Prior to any use, the LED spotlight should be charged first. To this effect, please
read the "Charging" section in these instructions for use.
Pass the hand strap with the thin loop through the recession on the bottom side of
the battery compartment lid first and then pull the broad ribbon through the thin
loop.
Operation
The DOCTER
aspherilux midi LED is fitted with a push-button for switch on and
®
off.
Charging
Basically, the charger may be used in closed rooms and for charging the
DOCTER
®
aspherilux midi LED only.
1. Connect the connecting cable (6) of the plug charger with the charging
station (5).
2. Put the DOCTER
charging station (5) as depicted below. Any wrong placement of the lamp
into the charging station is impossible.
3. Connect the plug charger (6) to a 220V mains outlet.
The control display on the plug charger indicates the charging process as follows:
LED
green
flash light
red
permanent light
green
permanent light
red
flash light
13
®
aspherilux midi LED in switched-off condition into the
Meaning
Mains connection is available
Quick charge is going on
Trickle charge is going on
An error has occurred