at least once a month. It is recommended that in situations
when whirl tub is not used for a longer time the whirl instal-
lation should be switched off from the power supply system
with the use of the master switch/FI. Minimum cross section
of the bath supply cable is 3x1,5 mm² (length L = 1,8 m). In
case of bathtubs equipped with an electric water heater (2
kW) a supply cable with cross section of 3x2,5mm² (length L
= 2.0 m) should be used. Fixed electrical connection of the
bath should be prepared in zone I (the unit is located under
the tub), compensatory connection should be provided ad-
ditionally. A marked clamp

02.04.1 Protected Area

area 2
area 1
60 cm
area 0
area 1
area 2
60 cm
area 0
is mounted on the bath frame,
area 2
60 cm
to which a compensating cable 4mm² should be connected.
Terminal made by the construction team should be in a form
of a permanent distributive damp-resistant socket (IP 65, at
least 30 cm over the fl oor, in the area under the bathtub).
When installing a bathtub attention should be paid to the
parts containing active elements (except for items supplied
with low safe voltage, i.e. not exceeding 12 V) which must
not be available for persons located in bathtub.
The fact that bathtub is connected to the electricity must be
noted in the warranty card with signature and seal of the au-
thorised person, which determines validity of the guarantee.
Do not use unit without positive earth connec-
tion (PE,
)!
Interrupt current connection before opening!
L
1
L
2
L
3
N
PE
RCD 30 mA
Main switch in bathroom
(Position outside area 2)
16A rccb
Equipotential bonding 4 mm²
19